100
APPX
Appendix 3 Connection with External Devices of the RD77MS
■
Voltage-output/Open-collector type
Make the cable within 10 m (32.81 ft.).
*1 Ground FG terminal on the used equipment side.
*2 The 5 V DC power supply from the Simple Motion module must not be used.
*3 Be sure to connect the 0 V (-) of the manual pulse generator/incremental synchronous encoder and the SG of the Simple Motion
module.
*4 Be sure not to be used except for supplying the power to the manual pulse generator.
HBL
When using the external power supply (Recommended)
HBH
HAL
HAH
HB
1B20
HA
1B19
HB
HA
1B15
SV
1B14
1A15
1A14
1A20
1A19
Voltage-output/open-collector type
Manual pulse generator/
Incremental synchronous encoder side
1B18
1B17
1A18
1A17
FG
*1
*3
5V
*2
5V
*2
5V
*2
5V
*2
SG
*3
SG
*3
HBL
When using the internal power supply
HBH
HAL
HAH
HB
1B20
HA
1B19
HB
HA
1B15
5V
0V
1B14
1A15
1A14
1A20
1A19
Voltage-output/open-collector type
Manual pulse generator/
Incremental synchronous encoder side
1B18
1B17
1A18
1A17
: Twisted pair cable
FG
*1
*3
*4
5V
*4
5V
*4
5V
*4
5V
*4
SG
*3
SG
*3