3 - 27
MDS-D-SVJ3/SPJ3 Series Specifications Manual
3-6 Diagnosis function
3-6-2 Machine resonance frequency display function
If resonance is generated and it causes vibrations of the current commands, this function estimates the
vibration frequency and displays it on the NC monitor screen (AFLT frequency).
This is useful in setting the notch filter frequencies during servo adjustment. This function constantly
operates with no need of parameter setting.
3-6-3 Machine inertia display function
With this function, the load current and acceleration rate during motor acceleration are measured to estimate
the load inertia.
According to the parameter setting, the estimated load inertia is displayed on the NC monitor screen,
expressed as its percentage to the motor inertia.
3-6-4 Motor temperature display function
The temperature sensed by the thermal sensor attached to the motor coil is displayed on the NC screen.
3-6-5 Load monitor output function
A spindle motor's load is output as an analog voltage of 0 to 3V (0 to 120%). To use this function, connect a
load meter that meets the specifications.
3-6-6 Open loop control function
This function is to run a spindle motor for operation check before or during the adjustment of the spindle
motor's detector. This allows the operation in which no detector feedback signals are used.
Summary of Contents for MDS-D-SPJ3
Page 1: ......
Page 3: ......
Page 5: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 27: ......
Page 31: ......
Page 39: ...1 8 ...
Page 65: ...2 26 ...
Page 93: ...3 28 ...
Page 169: ...5 58 ...
Page 233: ...Appendix 2 10 ...
Page 257: ...Appendix 4 20 ...
Page 280: ......
Page 284: ......