3-6 Diagnosis function
(Special output)
The result of PLG(TS5690) installation accuracy diagnosis is output to D/A output. D/A output
magnification:SP127(DA1MPY) and SP128(DA2MPY) is 0.
PLG installation diagnosis function can be enabled during the rotation, when open loop control is
enabled:SP018(SPEC2)/bit1=1.
D/A output
No.
Details
Description
120
Motor end PLG installation
Gap diagnosis
Motor end PLG installation gap is diagnosed.
When the gap is good, 2.5V is output.
When the gap is excessive, 2.5V+1V is output.
When the gap is too small, 2.5V-1V is output.
121
Motor end PLG installation
All errors diagnosis
Motor end PLG installation error (including the gap) is diagnosed.
When the installation is good, 2.5V is output.
When the installation is incorrect, 2.5V+1V is output.
122
Spindle end PLG installation
Gap diagnosis
Spindle end PLG installation gap is diagnosed.
Diagnostic procedure is the same as that of motor end PLG.
123
Spindle end PLG installation
All errors diagnosis
Spindle end PLG installation error (including the gap) is diagnosed.
Diagnostic procedure is the same as that of motor end PLG.
Summary of Contents for MDS-D-SPJ3
Page 1: ......
Page 3: ......
Page 5: ......
Page 17: ......
Page 19: ......
Page 21: ......
Page 27: ......
Page 31: ......
Page 39: ...1 8 ...
Page 65: ...2 26 ...
Page 93: ...3 28 ...
Page 169: ...5 58 ...
Page 233: ...Appendix 2 10 ...
Page 257: ...Appendix 4 20 ...
Page 280: ......
Page 284: ......