Appendix 4 - 16
Appendix 4 EMC Installation Guidelines
MITSUBISHI CNC
Appendix 4-6-4 Surge protector
Insert a surge protector in the power input section to prevent damage to the control panel or power supply unit,
etc. caused by the surge (lightning or sparks, etc.) applied on the AC power line.
Use a surge protector that satisfies the following electrical specifications.
< Surge protector for 200V >
200V R•A•V-BYZ Series (for protection between lines)
(Note)
Refer to the manufacturer's catalog for details on the surge protector's characteristics and
specifications.
Part name
Circuit
voltage
50/60Hz
Maximum
tolerable
circuit
voltage
Clamp
voltage
Surge
withstand
level
8/20 µs
Surge
withstand
voltage
1.2/50 µs
Electrostatic
capacity
Service
temperature
RAV-781BYZ-2
3AC 250V
300V
783V±10%
2500A
20kV
75pF
-20 to 70°C
28
.