3 - 34 3 - 34
MELSEC-Q
3 SPECIFICATIONS
Address
Decimal (Hex)
Application
Name
Initial
value
Protocol
Registration
Reference
section
CH1 CH2
MC Non Bi Pd
8256
(2040
H
)
8512
(2140
H
)
For designation
of programmable
controller CPU
monitoring
function
Cycle time units designation
2
R
— Allowed
User's Manual
(Application)
0: 100 ms
1: s
2: min
8257
(2041
H
)
8513
(2141
H
)
Cycle time designation
5
H
0
H
:
No
designation
1
H
to FFFF
H
: Programmable controller CPU monitoring cycle time
8258
(2042
H
)
8514
(2142
H
)
Programmable controller CPU monitoring function designation
0
0: Do not use the function.
1: Fixed cycle transmission
2: Condition agreement transmission
8259
(2043
H
)
8515
(2143
H
)
Programmable controller CPU monitoring transmission measure
designation
0
0: Data transmission (device data and CPU status data)
1: Notification
8260
(2044
H
)
8516
(2144
H
)
Transmission pointer designation (For fixed cycle transmission and
non-procedure data transmission)
0: No designation
1 to 100: Output head point (send from the nth)
Send the user frames designated in the following transmission
frame No. designation areas from the designated pointer
position.
(addresses: CH1 side = BA
H
to 11D
H
, CH2 side = 15A
H
to
1BD
H
)
—
R
8261
(2045
H
)
8517
(2145
H
)
Output count designation (for fixed cycle transmission and non-
procedure data transmission)
0: No designation
1 to 100: Output count (designate the number of frame
transmissions.)
8262
(2046
H
)
8518
(2146
H
)
Data No. for connection designation (for fixed cycle transmission
and notification)
R
0: No designation
0BB8
H
to 0BD5
H
, 8001
H
to 801F
H
: Data No. for connection
8263 to
8268
(2047
H
to
204C
H
)
8519 to
8524
(2147
H
to
2149
H
)
Use prohibited
System area
—
8269
(204D
H
)
8225
(214D
H
)
For designation
of programmable
controller CPU
monitoring
function
Number of registered word blocks designation
It is possible to
designate a
maximum of 10
blocks in total.
0
R
— Allowed
User's Manual
(Application)
0 :
No
designation
1 to 10: Number of blocks of word devices
8270
(204E
H
)
8226
(214E
H
)
Number of registered bit blocks designation
0 :
No
designation
1 to 10: Number of blocks of bit devices
8271
(204F
H
)
8527
(214F
H
)
Programmable controller
CPU abnormal monitoring designation
0: Do not monitor.
1: Monitor.
8272
(2050
H
)
8528
(2150
H
)
No. 1
block
monitoring
device
Monitoring device designation
0: No designation
90
H
to CC
H
: Device code
8273 to
8274
(2051
H
to
2052
H
)
8529 to
8530
(2151
H
to
2152
H
)
Head device No. designation
0 or more: Head device No.
8275
(2053
H
)
8531
(2153
H
)
Read point designation
0: No designation
1 or more: Number to read points
8276
(2054
H
)
8532
(2154
H
)
Monitoring condition designation (judgment condition
designation)
0: No designation
1 or more: Monitoring condition
8277
(2055
H
)
8533
(2155
H
)
Monitoring condition value designation
At bit device
0: OFF 1: ON
At word device 0 to FFFF
H
: Monitoring condition
value
8278
(2056
H
)
8534
(2156
H
)
Transmission pointer designation (for condition
agreement transmission and non-procedure data
transmission)
0: No designation
1 to 100: Output head point (send from nth)
Send the user frames designated in the following
transmission frame No. designation areas from the
designated pointer position.
(address: CH1 side = BAH to 11DH, CH2 side = 15AH
to 1BDH)
—
R
8279
(2057
H
)
8535
(2157
H
)
Output count designation (for condition agreement
transmission and non-procedure data transmission)
1 to 100: Output count (designate the number
of
frame
transmissions)
8280
(2058
H
)
8536
(2158
H
)
Data No. for connection designation (for condition
agreement transmission and notification)
R
0BB8
H
to 0BD5
H
, 8001
H
to 801F
H
: Data No. for
connection
Summary of Contents for GX Configurator-SC
Page 2: ......
Page 103: ...3 42 3 42 MELSEC Q 3 SPECIFICATIONS MEMO ...
Page 138: ...4 35 4 35 MELSEC Q 4 SETTINGS AND PROCEDURES PRIOR TO OPERATION MEMO ...
Page 397: ...App 24 App 24 MELSEC Q APPENDICES Connection example 3 Connection example 4 ...
Page 439: ...WARRANTY ...
Page 441: ......