1 - 13 1 - 13
MELSEC-Q
1 OVERVIEW
1.3 About Added/Changed Functions in Function Version B
The table below lists the functions that have been added or changed in the Q series
C24 of function version B.
POINT
(1) The added/changed functions shown in this section includes the functions
added in the first products of function version B or later.
For the function version, serial No., and software version of the Q series C24
and related products (CPU module, GX Developer, and GX Configurator-SC)
that can use the added/changed functions, refer to Section 2.7.
(2) See Appendix 1.1 concerning a comparison of functions in the different Q
series C24 function versions.
Function Outline
of
function
Supported module
Supported protocol
Reference
section
QJ71C24N
(-R2/R4)
QJ71C24
(-R2)
MC
Non
procedure
Bi-
directional
Pre-
defined
Simultaneous
connection of GX
Developer and GOT
This function allows access to the
programmable controller from a personal
computer with GX Developer and a GOT
connected to two different interfaces of the Q
series C24 at the same time.
1
2
Section 1.2
Control of RS(RTS) and
ER(DTR) signal states
This function allows the control of the on or off
state of the RS(RTS) and ER(DTR) signals
with the programmable controller program.
Section 3.2.1,
REMARKS
Support for 230, 400
bps
This function allows data communication with
an external device at a transmission speed of
230, 400 bps.
Chapter 4
Data
transmission/reception
at low speed
This function allows data communication with
an external device at a transmission speed of
50 bps.
Clearing reception data
by a dedicated
instruction
This function allows clearing reception data
using the CSET instruction during data
communication using the non procedure
protocol.
It is possible to clear the data even when data
is being transmitted.
Chapter 6,
Section 10.9
Programmable
controller CPU
information clear
This function clears the programmable
controller CPU information of the Q series
C24. (The programmable controller CPU
information is information about the access
target CPU type used in MC protocol
communications.)
Section
11.1.7
Transmission of the
programmable
controller CPU
monitoring information
through combined use
of the modem function
When the programmable controller CPU
monitoring function is active, this function
sends the monitoring information of the
programmable controller CPU to the external
device through the modem.
User's
Manual
(Application)
Automatic initialization
for modem
Initializes the modem automatically when Q
series C24 starts up.
User's
Manual
(Application)
Callback
After line connection from the GX Developer,
access to the QCPU from the GX Developer
is made possible through line reconnection
from the Q series C24 (callback).
Transmission costs after line connection from
the Q series C24 side are borne by the Q
series C24 side.
1 GX Developer cannot be connected to CH2 on the QJ71C24N and the QJ71C24N-R4.
2 GX Developer cannot be connected to CH2 on the QJ71C24.
Summary of Contents for GX Configurator-SC
Page 2: ......
Page 103: ...3 42 3 42 MELSEC Q 3 SPECIFICATIONS MEMO ...
Page 138: ...4 35 4 35 MELSEC Q 4 SETTINGS AND PROCEDURES PRIOR TO OPERATION MEMO ...
Page 397: ...App 24 App 24 MELSEC Q APPENDICES Connection example 3 Connection example 4 ...
Page 439: ...WARRANTY ...
Page 441: ......