3 - 14 3 - 14
MELSEC-Q
3 SPECIFICATIONS
3.4 Serial Communication Module Function List
The following table lists the functions of the Q series C24.
Function
Reference section
Communication using
MC protocol ( 1)
Communication with
ASCII code
Communication with QnA compatible 3C frame
Formats 1 to 4
exist for each.
Chapter 5
Reference Manual
Communication with QnA compatible 4C frame
Communication with QnA compatible 2C frame
Communication with A compatible 1C frame
Communication with
binary code
Communication with QnA compatible 4C frame Format 5
Read/write of device
memory
Batch read/write in bit/word units
Monitoring of device memory
Batch read/write of multiple blocks
Read/write by extension designation
Accessing other stations via network system
Reading/writing from/to the buffer memory of the Q series C24
Reading/writing from/to the buffer memory of intelligent function modules
Reading/writing from/to sequence program files
Monitoring the programmable controller CPUs (programmable controller CPU
monitoring function)
Status control of the programmable controller CPUs (remote RUN/STOP, etc.)
Turning on/off input signals of the Q series C24 from an external device (global
function)
Data transmission from a programmable controller CPU to an external device (on-
demand function)
Communication using
non procedure protocol
( 2)
Data transmission/reception in any format
Chapter 6
Data transmission/reception using user frames
User's Manual
(Application)
Data reception by interrupt programs
Monitoring the programmable controller CPUs (programmable controller CPU
monitoring function)
ASCII data transmission/reception by ASCII-BIN conversion
Data transmission/reception by specifying transparent code
Communication using
bidirectional protocol
( 1)
Data transmission/reception in any format
Chapter 7
Data reception by interrupt programs
User's Manual
(Application)
ASCII data transmission/reception by ASCII-BIN conversion
Data transmission/reception by specifying transparent code
Communication using
pre-defined protocol
( 2)
Data transmission/reception by a protocol selected from the pre-defined protocol
library
Chapter 8,
Operating Manual
(Pre-defined protocol
support function)
Data transmission/reception by a created or edited protocol
Communication via
public network, etc.
(modem function)
Communication with MC Protocol/non procedure protocol/bidirectional protocol
User's Manual
(Application)
Programmable controller access from GX Developer
Transmission control
DC code control (including Xon/Xoff control)
DTR/DSR control
Independent/linked operation of each interface
Section 4.5.2
Monitoring/testing of initial settings and setting values with utility software
Chapter 9
Supporting multiple CPU system
Reference Manual
Remote password check
User's Manual
(Application)
Echo back enable/disable setting for RS-422/485 interface
Section 3.3.4
1 If the external device is capable of incorporating a program and communicating
data using a protocol of a MELSEC programmable controller, it is possible to
access the programmable controller CPU using the MC protocol.
Communication of any data is also available using the bidirectional protocol.
Summary of Contents for GX Configurator-SC
Page 2: ......
Page 103: ...3 42 3 42 MELSEC Q 3 SPECIFICATIONS MEMO ...
Page 138: ...4 35 4 35 MELSEC Q 4 SETTINGS AND PROCEDURES PRIOR TO OPERATION MEMO ...
Page 397: ...App 24 App 24 MELSEC Q APPENDICES Connection example 3 Connection example 4 ...
Page 439: ...WARRANTY ...
Page 441: ......