37 Operation of Special Devices (M8000 -, D8000 -)
37.1 Special Device List (M8000 -, D8000 -)
31
FNC276
-F
NC2
79
Da
ta
Trans
fer 3
32
FNC28
0-F
NC
289
H
igh-Speed
Process
ing 2
33
FNC2
90-
FNC299
Ex
tensi
on Fi
le
Register
34
FN
C300-
FNC30
5
FX
3U
-C
F-
AD
P
35
SFC
•STL
Programming
36
Interrupt
Function
37
Sp
ec
ia
l D
evi
ce
38
E
rror Code
A
Ve
rsi
on U
p
Inform
ati
on
B
Ex
ecuti
on
T
imes
Pulse width/Pulse period measurement [FX
3G
PLCs ]
[M]8074
Not used
–
–
–
–
–
–
–
–
–
[M]8075
Pulse width/Pulse period measurement setting flag
3
*1
–
–
–
–
–
–
–
[M]8076
[X000] Pulse width/Pulse period measurement flag
3
*1
–
–
D8074 to
D8079
–
–
–
–
–
[M]8077
[X001] Pulse width/Pulse period measurement flag
3
*1
–
–
D8080 to
D8085
–
–
–
–
–
[M]8078
[X003] Pulse width/Pulse period measurement flag
3
*1
–
–
D8086 to
D8091
–
–
–
–
–
[M]8079
[X004] Pulse width/Pulse period measurement flag
3
*1
–
–
D8092 to
D8097
–
–
–
–
–
M 8080
[X000] Pulse period measurement mode
3
*1
–
–
D8074 to
D8079
–
–
–
–
–
M 8081
[X001] Pulse period measurement mode
3
*1
–
–
D8080 to
D8085
–
–
–
–
–
M 8082
[X003] Pulse period measurement mode
3
*1
–
–
D8086 to
D8091
–
–
–
–
–
M 8083
[X004] Pulse period measurement mode
3
*1
–
–
D8092 to
D8097
–
–
–
–
–
[M]8084 to [M]8089
Not used
–
–
–
–
–
–
–
–
–
*1.
Available in Ver. 1.10 or later.
Flag
[M]8090
BKCMP (FNC194 to FNC199) instructions - Block
comparison signal
–
3
3
*2
–
–
–
–
–
–
M 8091
COMRD (FNC182) and BINDA (FNC261) instructions -
Output character quantity selector signal
–
3
3
*2
–
–
–
–
–
–
[M]8092
Not used
–
–
–
–
–
–
–
–
–
[M]8093
–
–
–
–
–
–
–
–
–
[M]8094
–
–
–
–
–
–
–
–
–
[M]8095
–
–
–
–
–
–
–
–
–
[M]8096
–
–
–
–
–
–
–
–
–
[M]8097
–
–
–
–
–
–
–
–
–
[M]8098
–
–
–
–
–
–
–
–
–
High-Speed Ring Counter
M 8099
*3
High-speed ring counter operation (in units of 0.1ms, 16
bits)
–
3
3
D8099
–
–
3
–
3
[M]8100
Not used
–
–
–
–
–
–
–
–
–
*2.
Available in Ver. 2.20 or later.
*3.
For FX
2N
/FX
2NC
, 0.1ms high-speed ring counter D8099 will operate after END instruction is executed with
after M8099 is driven.
For FX
3U
/FX
3UC
, 0.1ms high-speed ring counter D8099 will operate after M8099 is driven.
Number and name
Operation and function
Applicable model
FX
3G
FX
3U
FX
3UC
Correspond-
ing special
device
FX
1S
FX
1N
FX
2N
FX
1NC
FX