33 Extension File Register Control – FNC290 to FNC299
33.5 FNC294 – RWER / Rewrite to ER
2) In FX
3G
PLCs
a) When a memory cassette is connected
The contents (current values) of “n” extension registers (R) starting from are written (transferred) to extension
file registers having with same device numbers in a memory cassette (flash memory).
b) When a memory cassette is not connected
The contents (current values) of "n" extension registers (R) starting from
are written (transferred) to
extension file registers which are stored in the EEPROM built into the PLC and have the same device
numbers.
FNC290
RWERP
S
n
Command
input
E
E +1
E +2
E +n-1
+1
+2
+n-1
*1
*1 All points specified by the instruction are written (transferred).
Write
(transfer)
Extension file registers (ER)
inside memory cassette
Extension registers (R) inside
built-in RAM