![Mitsubishi Electric FX3G SERIES Programming Manual Download Page 690](http://html.mh-extra.com/html/mitsubishi-electric/fx3g-series/fx3g-series_programming-manual_238902690.webp)
688
FX
3G
/FX
3U
/FX
3UC
Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
30 External Device Communication (Inverter Communication) – FNC270 to FNC275
30.1 FNC270 – IVCK / Inverter Status Check
2. Inverter instruction codes
The table below shows inverter instruction codes which can be specified in
. Only use the instruction codes
shown below. Use of instruction codes not shown below may cause communication errors.
Do not use instruction codes not shown in the table below. They may cause communication errors.
For the instruction codes, refer to the pages explaining computer link in detail in each inverter manual.
3. Related devices
→
For the instruction execution complete flag use method, refer to Subsection 6.5.2.
*1.
Cleared when PLC power supply is turned from OFF to ON.
*2.
Cleared when the PLC mode switches from STOP to RUN.
*3.
Initial value: -1
Cautions
→
For other cautions, refer to the Data Communication Edition manual.
• It is not permitted to use an "RS (FNC 80)/RS2 (FNC 87)"/"FLCRT (FNC300) to FLSTRD (FNC305)" instruction and
an "IVCK (FNC270) to IVMC (FNC275)" instruction for the same port.
• Two or more inverter communication instructions (FNC270 to FNC275) can be driven for the same port at the same
time.
PLC applicable version
The table below shows PLC versions applicable to each inverter.
Inverter Instruction
code (hexadecimal)
Read contents
Applicable inverter
F700
A700
E700
D700
V500
F500
A500
E500
S500
H7B
Operation mode
3
3
3
3
3
3
3
3
3
H6F
Output frequency
(speed)
3
3
3
3
3
3
3
3
3
H70
Output current
3
3
3
3
3
3
3
3
3
H71
Output voltage
3
3
3
3
3
3
3
3
–
H72
Special monitor
3
3
3
3
3
3
3
–
–
H73
Special monitor selection No.
3
3
3
3
3
3
3
–
–
H74
Alarm definition
3
3
3
3
3
3
3
3
3
H75
Alarm definition
3
3
3
3
3
3
3
3
3
H76
Alarm definition
3
3
3
3
3
3
3
3
–
H77
Alarm definition
3
3
3
3
3
3
3
3
–
H79
Inverter status monitor
(expansion)
3
3
3
3
–
–
–
–
–
H7A
Inverter status monitor
3
3
3
3
3
3
3
3
3
H6E
Set frequency
(EEPROM)
3
3
3
3
3
3
3
3
3
H6D
Set frequency (RAM)
3
3
3
3
3
3
3
3
3
Number
Description
Number
Description
ch1
ch2
ch1
ch2
M8029
Instruction execution complete
D8063
D8438
Error code of serial communication error
*1
M8063
M8438 Serial communication error
*1
D8150
D8155
Response wait time in inverter communication
*1
M8151
M8156 Inverter communicating
D8151
D8156
Step number in inverter communication
*3
M8152
M8157 Inverter communication error
*2
D8152
D8157
Error code of inverter communication error
*2
M8153
M8158 Inverter communication error latch
*2
D8153
D8158
Latch of inverter communication error occurrence
step
*2*3
M8154
M8159 IVBWR instruction error
*2
D8154
D8159
IVBWR instruction error parameter number
*2*3
PLC
FREQROL-V500/F500/A500/E500/S500
FREQROL-F700/A700
FREQROL-E700/D700
FX
3G
Ver. 1.10 or later
FX
3U
Ver. 2.20 or later
Ver. 2.32 or later
FX
3UC
Ver. 1.00 or later
Ver. 2.20 or later
Ver. 2.32 or later
S
2
S