PARAMETER DEFINITIONS - A500/F500 SERIES
54
The following parameters require the Sub-Index number for the PNU.
Pr.
Number
PNU
Name
Minimum
Setting
Increments
Setting Range
Data
Type
Remarks
Decimal
Hexadecimal
201 to
210
P1201.1
to
P1210.1
Program
setting 1
(Time)
0.01
0 to 99.59
0 to 26E7
AUs16
A500
series
parame-
ters
P1201.2
to
P1210.2
Program
setting 1
(Rotation
direction)
1
0 to 2
0 to 2
AUs16
P1201.3
to
P1210.3
Program
setting 1
(Frequency)
0.1Hz
0 to 400,
9999
0 to 9C40,
FFFF
AUs16
211 to
220
P1211.1
to
P1220.1
Program
setting 2
(Time)
0.01
0 to 99.59
0 to 26E7
AUs16
P1211.2
to
P1220.2
Program
setting 2
(Rotation
direction)
1
0 to 2
0 to 2
AUs16
P1211.3
to
P1220.3
Program
setting 2
(Frequency)
0.1Hz
0 to 400,
9999
0 to 9C40,
FFFF
AUs16
221 to
230
P1221.1
to
P1230.1
Program
setting 3
(Time)
0.01
0 to 99.59
0 to 26E7
AUs16
P1221.2
to
P1230.2
Program
setting 3
(Rotation
direction)
1
0 to 2
0 to 2
AUs16
P1221.3
to
P1230.3
Program
setting 3
(Frequency)
0.1Hz
0 to 400,
9999
0 to 9C40,
FFFF
AUs16
900
P1900.1
FM terminal
calibration
-
-
-
AUs16
901
P1901.1
AM terminal
calibration
-
-
-
AUs16
902
P1902.1
Frequency
setting
voltage bias
(frequency)
0.01Hz
0 to 60
0 to 1770
AUs16
P1902.2
Frequency
setting
voltage bias
(%)
0.1%
-
-
AUs16