INVERTER SETTING
16
External
: Control by signal from external terminal is only valid.
NET
: Control from Profibus master module
is only valid.
Combined
: Control from both external terminal and Profibus master module
is valid.
—
: Control from both external terminal and Profibus master module
is invalid.
Compensation : Control by signal from external terminal is only valid if Pr. 28
"multi-speed input compensation" setting is "1".
*1 If the FR-HC connection, FR-CV connection (inverter operation enable signal)
(X10) is not assigned when "2" is set in Pr. 30 "regenerative function selection"
(when the FR-HC or FR-CV is used) or if the PU operation interlock signal
(X12) is not assigned when "7" (when the PU operation interlock function is set)
is set in Pr.79 "operation mode selection" , this function is also used by the
MRS terminal and therefore operation is only valid for the external terminal,
independently of Pr. 338 and Pr. 339 settings.
*2 When the MRS signal is assigned to both network and external control, the
output stop command is as listed below:
*3 This setting is valid only when the FR-A5AP option is mounted. (The FR-A5AP
cannot be used with the FR-F500 series.)
*4 Programmed operation is available only with the FR-A500 series.
S
e
le
c
ti
v
e f
u
nc
ti
o
n
s
P
r. 18
0 t
o
P
r.
186
set
ti
ngs
17
Load pattern selection-forward/
reverse rotation boost switching
(X17)
NET
NET
External
External
18 Magnetic flux-V/F switching (X18)
NET
NET
External
External
19
Load torque high-speed frequency
(X19)
NET
NET
External
External
20
S-pattern acceleration/
deceleration C selection terminal
(X20) *3
NET
NET
External
External
22 Orientation command (X22) *3
NET
NET
External
External
23 Pre-excitation (LX) *3
NET
NET
External
External
RH, RM,
RL, RT
selective
functions
Remote setting (RH, RM, RL)
NET
External
NET
External Pr. 59 = 1, 2
Programmed operation group
selection (RH, RM, RL) *4
—
—
—
—
Pr. 79 = 5
Network
operation is
disabled
Stop-on-contact selection 0 (RL) *4
NET
External
NET
External Pr. 270 = 1,
3
Stop-on-contact selection 1 (RT) *4
NET
NET
External
External
Control
location
selection
Pr. 338 "operation control
command source"
0: NET
0: NET
1: External 1: External
REMARKS
Pr. 339 "speed command
source"
0: NET
1: External
0: NET
1: External
Network
External
Output Stop Command
Pr. 17 = 0
Pr. 17 = 2
ON
ON
Output stopped
Output not stopped
ON
OFF
Output stopped
Output stopped
OFF
ON
Output stopped
Output stopped
OFF
OFF
Output not stopped
Output stopped