4. Setting up MELDASMAGIC64 System
4.7 Setting Up NC data
72
4.7.3 Setting Up NC Parameters
Here, set up and adjust NC parameters according to the machine configuration and machine
specifications. Use MELDASMAGIC Monitor to set up and adjust NC parameters.
Start MELDASMAGIC Monitor (magicmon.exe).
[Procedures]
(1) Click the [Programs] - [MELDASMAGIC] - [MELDASMAGIC Monitor] menus from the taskbar
[Start] menu, and start MELDASMAGIC Monitor.
Set up and adjust NC parameters according to the machine configuration and machine
specifications.
Refer to "MELDASMAGIC Monitor Operation Manual (BNP-B2192)" for MELDASMAGIC Monitor
handling. Refer to "MELDAS60/60S series Operation Manual (BNP-B2180)" for the screens and
parameters.
Exit Windows, and restart the personal computer.
Start the MELDASMAGIC monitor again.
Format the NC file system.
[Procedures]
(1) Open the “Setup Parameters” menu from MELDASMAGIC Monitor.
(2) Set "1" on the [#1060 Setup] parameter of [BASE SPEC. PARAM], and then press the Enter key.
Operation: The message of " BASE PARA SET (Y/N)" appears in the MELDASMAGIC Monitor
window.
(3) Set "N," and then press the Enter key.
Operation: The message of "FORMAT ? (Y/N)" appears in the MELDASMAGIC Monitor window.
(4) Set "Y," and then press the Enter key.
Operation: The NC file system is formatted. When formatting has finished, the message of
"SETUP COMPLETE" is displayed.