4. Setting up MELDASMAGIC64 System
4.7 Setting Up NC data
70
4.7 Setting Up NC data
Parameters, ladder programs and so on will be lost when NC Card is started up for the first time or NC
Card memory is erased in changing batteries. In this case, set up these data according to the
procedures below.
4.7.1 Installing NC Standard Parameters
Install NC standard parameters using the file transfer utility (magictrs.exe) to copy the NC standard
parameter file to NC Card.
Install NC standard parameters according to the procedures below.
Overwrite the "paramet.bin" file on the "NC Data (64x)" floppy disk to the
"\PRM\PARAMET.BIN" file on NC Card using the file transfer utility (magictrs.exe).
* Here, select M, L, D, or G for the x of "64x".
[Procedures]
(1) Insert the floppy disk titled "NC Data (64x)" into drive A.
* Here, select M, L, D, or G for the x of "64x".
(2) Click [Programs] - [MELDASMAGIC] - [File Transfer] menus from the taskbar [Start] menu, and
then start the file transfer utility.
(3) Select the "A:\paramet.bin" file on the [PC] side of the "File Transfer" window.
(4) Select the "Mxx:\PRM\" directory on the [NC] side.
* Here, specify the NC Card No. being set up on the xx of "Mxx."
(5) Click the
button for copying parameters (from the personal computer to NC Card) to copy
parameters.
Operation: Files are overwritten.
Exit the file transfer utility.
Exit Windows, and restart the personal computer.
Downloaded from