2. Combination with indoor units
The indoor units connectable to this unit are shown below.
Model name of connectable indoor unit
Outdoor unit model
name
PMFY-P25 · 32 · 40 · 63
VBM
PLFY- P32 · 40 · 50 · 63 · 80 · 100 · 125
VKM
PLFY- P25 · 32 · 40 · 50 · 63 · 80 · 100 · 125
VLMD
PEFY- P25 · 32
VML
PEFY- P40 · 50 · 63 · 71 · 80 · 100 · 125 · 140 · 200 · 250
VMH
PCFY- P40 · 63 · 100 · 125
VGM
PKFY- P25
VAM
PKFY- P32 · 40 · 50
VGM
PFFY- P25 · 32 · 40 · 50 · 63
VLEM
PFFY- P25 · 32 · 40 · 50 · 63
VLRM
PDFY- P25 · 32 · 40 · 50 · 63 · 71 · 80 · 100 · 125
VM
Total capacity of
connected indoor unit
models
Quantity of connectable
indoor unit
200 to 520
PUHY-P400
2 to 20
250 to 650
PUHY-P500
Note:
1. The total capacity of connected indoor unit models represents the total sum of the figures expressed in the indoor model name.
2. Combinations in which the total capacity of the connected indoor units exceeds the capacity of the outdoor unit will reduce the capacity
of each indoor unit below the rated capacity during simultaneous operation. Therefore, if circumstances allows, combine indoor units
within the capacity of the outdoor unit.
3. A transmission booster (RP) is required when the number of connected indoor unit models in a cooling system exceeds the number of
models specified in the chart below.
* The maximum number of units that can be controlled is determined by the indoor unit model, the type of remote controller and their
capabilities.
The number of indoor units and the total number of remote controllers is displayed within the parenthesis (
).
*1 If even one unit that is higher than 200 exists in the cooling system, the maximum capacity will be “200 or higher”.
200 or lower
200 or higher
(*1)
Capability of the
connected indoor units
Number of connected indoor units that can be
connected without a RP.
Remote controller type
This outdoor unit is attached with the parts below. Please check the quantity for each item.
Name
1
Conduit mounting plate
2
Conduit mounting plate
3
Conduit mounting plate
4
Tapping screw M4
×
10
Shape
PUHY-P400
PUHY-P500
1
1
1
6
Name
5
Connecting pipe
6
Packing
7
Wire mounting plate
Shape
PUHY-P400
PUHY-P500
1
1
1
*
5
Connecting pipe is fixed with the unit.
3. Confirmation of parts attached
Model name
Model name
ø62
ø53
ø46
inside ø29, outside ø39