16
–800 to +800, the default value being set at 0. Perform the following steps to
adjust saturation:
1. Press SELECT to enter the menu.
PROC
is displayed..
2. Press SELECT to enter the ProcAmp menu.
Y
is displayed. Depress the “+”
push-button until
SAT
is displayed.
3. Press SELECT to enable the saturation menu. The current value is displayed.
4. Use the “+” or “–“ push-button to set the required saturation value. Press the
“+ “ and “–“ push-buttons simultaneously to set the saturation value to default.
5. Press SELECT to store the new saturation value.
6. Press ESC to return to
PROC
.
7. To return to normal mode, press ESC.
3.4.4 Black Level Adjustment
The black level (luma) adjustment ranges from –100 to +100, default value being
set at 0. Perform the following steps to adjust the black level:
1. Press SELECT to enter the menu.
PROC
is displayed..
2. Press SELECT to enter the ProcAmp menu.
Y
is displayed. Depress the “+”
push-button until
BLAK
is displayed.
3. Press SELECT to enable the black level adjustment menu. The current value
is displayed.
4. Use the “+” or “–“ push-button to set the required black level. Press the “+“
and “–“ push-buttons simultaneously to set the black level to default.
5. Press SELECT to store the new black level.
6. Press ESC to return to
PROC
.
7. To return to normal mode, press ESC.
3.4.5 Hue Adjustment
The hue adjustment ranges from –180° to +180° in steps of 0.5°, the default being
set at 0 . Perform the following steps to adjust the hue:
1. Press SELECT to enter the menu.
PROC
is displayed..
2. Press SELECT to enter the ProcAmp menu.
Y
is displayed. Depress the “+”
push-button until
HUE
is displayed.
3. Press SELECT to enable the hue adjustment menu. The current value is
displayed.
4. Use the “+” or “–“ push-button to set the required hue value. Press the “+“ and
“–“ push-buttons simultaneously to set the hue to default.
5. Press SELECT to store the new hue value.
6. Press ESC to return to
PROC
.
7. To return to normal mode, press ESC.
3.4.6 Cable Equalization
The cable equalization parameter compensates for poorly adjusted cable
equalization in an upstream device. It will correct the frequency response for cable
lengths of up to 500 feet. The equalization ranges from –32 to +32, default being
set at 0. Perform the following steps to set cable equalization:
1. Press SELECT to enter the menu.
PROC
is displayed..