![Miranda DVP-101i Manual To Installation And Operation Download Page 29](http://html.mh-extra.com/html/miranda/dvp-101i/dvp-101i_manual-to-installation-and-operation_1805587029.webp)
24
FLD 1 (field 1)
FLD 2 (field 2)
Displays field 1 or field 2 on a manual freeze. For an
automatic freeze, it will display the last good field.
FRM (frame)
Displays the current frame on a manual freeze. For an
automatic freeze, it will display the last good field (no freeze
on last good frame is required).
BLAK (black)
Displays a black frame at the output
3.8.3 Input Video Freeze Detection
In addition to providing an automatic freeze on incoming signals with detected
errors, the DVP-101i has the ability to detect that the incoming video itself is
frozen. An alarm is raised once the frozen state has been detected for longer than
a user-specified period. The alarm will be announced on the card itself (the card-
edge ERR LED will illuminate and the display will show INFZ), on the rear-panel
GPI output, and on iControl.
This feature is very useful when the DVP-101i is processing video coming from a
circuit prone to failure, such as an MPEG satellite receiver. When most receivers
lose the satellite carrier, they freeze their output but do not send an alarm. A DVP-
101i with Input Video Freeze Detect enabled will identify the frozen video and
raise the alarm.
To select the detection period, or turn the feature off, perform the following steps:
1. Press SELECT to enter the menu.
PROC
is displayed.
2. Press the “+“ push-button until
INFZ
is displayed.
3. Press SELECT to enable the Input Freeze menu. The current selection
is
displayed (either OFF or a time interval in seconds).
4. Use the “+” or “–“ push-button to choose the desired status. Press the “+“ and
“–“ push-buttons simultaneously to set the status to
0FF
(default setting).
5. Press SELECT to store the new status.
INFZ
is displayed.
6. To return to normal mode, press ESC.
3.9 Composite Output Settings
3.9.1 Setup Level
The setup level for the composite output can be set to 0 IRE or 7.5 IRE, in NTSC
only. Thus this menu is only available when a valid NTSC input signal is used. To
select the desired setup level, perform the following steps:
7. Press SELECT to enter the menu.
PROC
is displayed.
8. Press the “+“ push-button until
COMP
is displayed.
9. Press
SELECT;
SETP
is displayed.
10. Press SELECT to enable the Setup Level menu. The current setup selection
is displayed.
11. Use the “+” or “–“ push-button to choose the desired setup. Press the “+“ and
“–“ push-buttons simultaneously to set the setup level to
0
(default setting).
12. Press SELECT to store the new setup level.
SETP
is displayed.
13. Press ESC to return to
COMP
.
14. To return to normal mode, press ESC.
3.9.2 Color Framing Control