9 - Ethernet IP
57 / 66
9.3
Process data
The configuration for process data is the following:
•
Assembly 0x64 (Originator to Target,
DBS55 inputs - PLC outputs
)
Assembly length : 50bytes
Offset
Type
Attribute
Class Instance Attribute
Default
Meaning
0x00 U16 ControlWord
0x67
0x60
0x40
0000h
See Dsp402
0x02
S32 TargetPosition
0x67
0x60
0x7A
+0
Pulses
0x06 U16 TorqueLimit
0x67
0x60
0x72
1000
x 0.1% Trq
0x08
S32 TargetVelocity
0x67
0x60
0xFF
+0
Rpm
0x0C
S16 TargetTorque
0x67
0x60
0x71
+0
x 0.1% Trq
0x0E
U8 ModeOfOperation
0x67
0x60
0x60
1
ProfilePosition
See Dsp402
0x0F U32 ProfileVelocity
0x67
0x60
0x81
+3000
Rpm
0x13 U32 ProfileAcceleration
0x67
0x60
0x83
+3000
Rpm/s
0x17 U32 ProfileDeceleration
0x67
0x60
0x84
+3000
Rpm/s
0x1B
S32 PositionLimit.Neg
0x67
0x60
0x7D.1
-2147483648
Pulses
0x1F
S32 PositionLimit.Pos
0x67
0x60
0x7D.2
+2147483647
Pulses
0x23
S32 HomingOffset
0x67
0x60
0x7C
+0
Pulses
0x27
S16 HomingMethod
0x67
0x60
0x98
37
SetQuota
See Dsp402
•
Assembly 0x65 (Originator to Target,
DBS55 outputs - PLC inputs
)
Assembly length : 20bytes
Offset
Type
Attribute
Class Instance Attribute
Default
Meaning
0x00 U16 StatusWord
0x67
0x60
0x41
0250h
See Dsp402
0x02
S32 PositionActualValue
0x67
0x60
0x64
+0
Pulses
0x06
S16 TorqueActualValue
0x67
0x60
0x77
+0
x 0.1% Trq
0x08
S32 VelocityActualValue
0x67
0x60
0x6C
+0
Rpm
0x0C U16 VDclink
0x67
0x30
0x10
+0
x 0.1V
0x0E
U8 ModeOfOperation
0x67
0x60
0x60
1
See Dsp402
0x0F U16 ActualAlarm
0x67
0x30
0x08
0
See DBS
Manual