5 - Led
34 / 66
5.5
Fieldbus Board Ethernet ProfiNet IO
The indication LEDs are three:
LD1
SF
System Failure
RED LED
LD2
BF
Bus Failure
RED LED
LD3
L/RX/TX
(Link / RX-TX Activity)
Bicolour LED
and they are mapped on the
drive’s LEDs in the following way:
LD1
LD2
LD3
SF
BF
L/RX/TX
LED mapping on the drive
LED
Indication
(*)
Status
LD1
SF
OFF
No error
ON (Red)
Error
Watchdog timeout; channel, generic or extended
diagnosis present; system error
FLASHING
(Red, 1Hz, 3 s)
DCP signal service
is initiated via the bus
LD2
BF
OFF
No error
ON (Red)
Error:
No configuration or low speed physical link; or no
physical link
FLASHING
(2 Hz Red)
No data exchange
LD3
LINK
OFF
No connection:
The device has no connection to the
Ethernet.
ON (Green)
Link
: A connection is linket to the Ethernet
RX/TX
FLICKERING
(Load dependent, Yellow)
Activity
: A connection to the Ethernet exists.
OFF
No Activity:
The device does not send/receive Ethernet
frames
.