5 - LED status
27 / 66
5
LED status
LED color and operating modes (flashing / powering mode) depend on the fieldbus expansion Board
mounted (i.e. CanOpen, Ethercat, etc).
5.1
Fieldbus Board CanOpen\Modbus
The indication LEDs are three and they are mapped on the drive’s LEDs in the following
way:
LD1
LD2
LD3
LED mapping on the drive
LED
Indication
(*)
Status
LD1
FLASHING
(Red)
Inverter alarm
Tacc=0.5s
Tperiod=1s
FLASHING
(Red)
PWM off
The number of flashes represent the type of control set:
•
0 flashes: unchecked control;
•
1 flash: torque control;
•
2 flashes: speed control;
•
3 flashes: position control.
ON (Red)
PWM on
LD2
OFF
Yellow led always off
LD3
OFF
Inverter alarm
FLASHING
(Green)
PWM off
The number of flashes represents the source of the
reference:
•
1 flash: Analog reference;
•
3 flashes: Modbus reference;
•
4 flashes: Multispeed reference;
•
5 flashes: reference via CanOpen.
ON (Green)
PWM on
(Intermittent speed proportional to the rotation
speed in relation to P006 parameter)