102
Figure 93
System Warning
15.4.7 Checking the secondary unit
1. Verify that the secondary unit is up and running.
2. Verify that the secondary unit is in secondary unit mode.
To do so:
Log in to the secondary unit as an administrator. Check that the unit is in secondary
unit mode. If it is not, follow the steps in section
15.4.2 on page 98.
15.4.8 Redoing the secondary and primary unit configuration
Where the secondary unit is verified as up and running and is in secondary unit
mode, but the
Secondary unit not responding
or
Secondary
unit
not
replicating
notification persists, do the following:
Convert both the secondary and primary units to standalone mode. To do so:
1. At the primary unit login to the AccessIT web interface. From the
Settings/Maintenance
menu, click
Replication
. Select
Standalone
Unit
.
2. At the secondary unit login to the AccessIT web interface and press
. The unit reboots in Standalone mode
3. Convert the secondary unit to secondary unit mode. See section
15.4.2 98
4. Convert the primary unit to primary unit mode. See section
15.4.3 on page 99.
The system should now be operational.