background image

3

 

Signum 3 Ex

 

Intended Use

  Intended Use

 Signum

® 

3 is a precise and rugged 

complete scale that gives you reliable 

weighing results�

  The Signum

®

 Series of compact scales 

includes models with monolithic tech-

nology, using the principle of electro-

magnetic force compensation�

  These compact industrial scales offer 

the following special features:

–  Rugged and durable Minebea Intec 

quality

–  Flexible options for display unit instal-

lation

–  Wide range of configuration options for 

customized operation

–  Variety of optional data interfaces

–  Optional IP65 protection from dust and 

jets of water ( SIWXS***-06: IP 43 ) 

–  High quality workmanship and materi-

als 

–  Various application programs

–  Available in weighing capacities 

between 0�6kg and 35kg;  

choice of resolutions available for each 

capacity

–  Preload values can be defined (for 

equipment installed on the scale)

–  Display can be decoupled from the 

weighing technology

–  Use in potentially explosive atmo-

spheres, zones 1 /21

  ( SIWXS***-06: Ex Zone 1 )

  Additional features include:

–  large keys with positive click action

–  Numeric and alphabetic input

–  Large backlit 14-segment display

  Advantages in routine weighing tasks:

–  Fast response times

–  Independence from location of platform 

installation

–  Designation of weight values with up to 

4 lines of alphanumeric text

–  Security through password protection

  Range of Models

 

Signum

®

 Supreme 

  SIWXSDCP models:

–  Monolithic weighing system

–  Resolutions up to 350,000d

 

  SIWXSBBP models:

–  Monolithic weighing system

–  Resolutions up to 620,000d

 Signum

®

 Supreme  

   featuring a stainless steel 

housing

  SIWXSDCS/SIWXSBBS models:

–  Monolithic weighing system

–  Resolutions up to 610,000d

 

 

Explanation of Symbols

  The following symbols are used in the 

text:

§

  Denotes general operating instructions 

$

  special instructions for exceptional 

cases

>  Describes the outcome of an operating 

step

!

 Indicates a hazard 

   Technical Advice on Applications/

Hotline

 Phone: +49�40�67960444

 Fax: 

+49�40�67960474

  E-mail:   technical�support�hh 

 @minebea-intec�com

Summary of Contents for Signum 3 Ex

Page 1: ...Operating Manual Minebea Intec Signum 3 Ex Model SIWXSBBP SIWXSBBS SIWXSDCP SIWXSDCS Complete Scales for Use in Explosive Atmospheres 98648 019 47...

Page 2: ...compliant Printouts 85 Error Codes 86 Care and Maintenance 87 Disposal 87 Common Specifications 88 Signum Model Designator 88 Model specific Specifications 89 Dimensions Scale Drawings 91 Accessories...

Page 3: ...eighing technology Use in potentially explosive atmo spheres zones 1 21 SIWXS 06 Ex Zone 1 Additional features include large keys with positive click action Numeric and alphabetic input Large backlit...

Page 4: ...th your Signum scale Contact your local Minebea Intec office dealer or service center IP Protection The IP43 or optional IP65 protection rating for the display and control unit is ensured only if the...

Page 5: ...ner bracket Take the cable out of the cable channel Turn the weighing platform right side up and place it so that it rests on its feet Level the weighing platform see page 7 Installing the display and...

Page 6: ...platform to the bottom of the column Turn the weighing platform right side up and place it so that it rests on its feet Attach the cable retainer to affix the cable connecting the display and control...

Page 7: ...ide of explosion risk areas only YPS02 X or YPSC01 X for use inside explosion risk areas When operating a scale in an explosive area Follow all current standards and regulations for the installation o...

Page 8: ...Funktion anwendungsabh ngig R ckseite 20 RS232C Schnittstelle COM1 Standard 21 Netzkabelanschluss Signum 3 20 21 20 21 21 Display and Keypad 1 Display for details see the chapter entitled Operating Co...

Page 9: ...men Nullstellen Abbrechen Kalibrieren Justieren Zum Tarieren k Umschalten je nach Setup Vorgabe zwischen erster und zweiter W ge einheit Brutto und Nettoangaben oder normaler und 10 facher Aufl sung J...

Page 10: ...esponding key For example press to save manual tare input To delete a digit Press the c key Loading a Tare Value from the Weighing Platform To save the weight on the weighing platform as a tare weight...

Page 11: ...eige Datentransfer Speicher Z hlen Referenzoptimierung Autom Summieren Anzeige Display Es gibt zwei grunds tzliche Display Darstellungen Darstellung f r den normalen Betrieb W gebetrieb Ger tezustand...

Page 12: ...r minus sign of the value displayed 20 Busy symbol indicates that an internal process in progress Saving Data in Weighing Mode All of the application parameters saved e g reference values remain in me...

Page 13: ...em k Cursor in first position no characters entered yet Delete character s and enter 0 Change the displayed character scroll backwards sequence 0 9 decimal point minus sign Z _ A space p Cursor in fir...

Page 14: ...l functions Four data outputs transfer signals for less than equal to greater and set You can define whether the outputs are always active or are activated only at stability only within the checkweigh...

Page 15: ...setting English with U S date time French Italian Spanish Printing parameter settings Press the p key in Setup Scope of printout Depends on the position in Setup Language Settings Example Selecting U...

Page 16: ...er k 5 Select the CODE menu item press k repeatedly until U CODE is displayed 6 Select the menu item user password p p 7 Enter the first character using the p and k keys in this example A 8 Save the c...

Page 17: ...e when minimum sample quantity has been entered by Service and menu item SQMIN DISPLAY ON Operating Menu Overview In the Setup menu you can configure the display and control unit to meet your individu...

Page 18: ...ts 3 6 5 20 digits 3 6 6 50 digits 3 6 7 100 digits 3 6 8 200 digits 3 6 9 500 digits 3 6 10 1000 digits 3 9 Resolution for calculation of reference value 3 9 1 Display accuracy 3 9 2 Display accuracy...

Page 19: ...1 2 With increased stability V anim wg Averaging animal weighing 3 6 Minimum load threshold for automatic start Numeric menu similar to Counting 3 18 Start of averaging 3 18 1 Manually 3 18 2 Automati...

Page 20: ...ulated values 3 15 1 Residue 3 15 2 Loss appl 2 O check wg Checkweighing 4 2 Checkweighing range 4 2 1 30 to 170 4 2 2 10 to infinity 4 3 Control output for SET as 4 3 1 Output SET 4 3 2 Process contr...

Page 21: ...time with the O key 3 17 3 Print the entire standard print configuration once with the O key Vorzeichen S oder D f r W gewert oder verrech neten Wert U f r Nullstellung oder bei tarierter W geplattfor...

Page 22: ...lication 2 3 23 Saved value 3 23 1 Net 3 23 2 Calculated 3 23 3 Net and Calculated Off SETUP ctrl io 8 4 Function for external key universal 8 4 1 Trigger p key function 8 4 2 Trigger p key function p...

Page 23: ...ations when you switch on the device with most recently saved application data 3 8 1 Automatic On 3 8 2 Manual Off sel cf 3 24 Selective deleting with the c key 3 24 1 Deletes all applications 3 24 2...

Page 24: ...1 Without stability 1 5 2 After stability 1 6 Autozero 1 6 1 On 1 6 2 Off 1 7 Weight unit 1 2 1 7 1 Gram o 1 1 7 2 Gram g 1 7 3 Kilogram kg 1 7 4 Carat ct 1 1 7 5 Pound lb 1 1 7 6 Ounces oz 1 1 7 7 T...

Page 25: ...17 1 Gram 1 17 2 Kilogram 1 17 4 1 Pound 1 18 Entering adjustment weight 1 18 1 External user adjustment weight enter value e g 10 000 kg 3 1 Weight unit 2 3 3 1 1 Gram o 1 3 1 2 Gram g 3 1 3 Kilogram...

Page 26: ...r of stop bits 5 3 1 1 stop bit 5 3 2 2 stop bits 5 4 Handshake mode 5 4 1 Software handshake 5 4 3 Hardware handshake 1 character after CTS 5 6 Number of data bits 5 6 1 7 data bits 5 6 2 8 data bits...

Page 27: ...display updates 6 3 4 10 display updates 6 3 7 100 display updates 7 2 Data output Line format 7 2 1 For raw data 16 characters 7 2 2 For other applications 22 characters 9 1 Restore factory settings...

Page 28: ...umeric menu similar to SBI Printer COM1 RS232 or RS422 Printer configuration YDP20 YDP20 5 1 Baud rate 5 1 4 1200 Baud 5 1 5 2400 Baud 5 1 6 4800 Baud 5 1 7 9600 Baud 5 1 8 19200 Baud 5 2 Parity 5 2 2...

Page 29: ...top bits 5 4 Handshake mode 5 4 1 Software handshake 5 4 3 Hardware handshake 1 character after CTS 5 6 Number of data bits 5 6 1 7 data bits 5 6 2 8 data bits YDP05 4 YDP05 YDP04IS line Strip printer...

Page 30: ...4 5 ID 3 ID code name for ID 3 max 20 characters 7 4 6 ID 4 ID code name for ID 4 max 20 characters 7 5 Quantity of individual printout interface 1 7 5 1 1 printout 7 5 2 2 printouts 7 6 Configuratio...

Page 31: ...ility off 7 15 2 One time auto print at stability on 7 16 Flex print 7 16 1 OFF 7 16 2 ON 7 17 Decimal separator 7 17 1 Period 7 17 2 Comma 7 18 Printout of Alibi and product data memory 7 18 1 1 Sele...

Page 32: ...off acc to menu item 8 9 8 7 2 No automatic shutoff 8 8 Display lighting 8 8 1 On 8 8 2 Off 8 8 3 Automatic shutoff acc to menu item 8 9 8 9 Timer 8 9 1 After 1 1 minute not in use after 1 min warning...

Page 33: ...SIWXSBBP 3 3 H 1 Model type 10405355 2 Serial number 00 37 2B3 Software version S3 207 171214 4 Application version 52 5 Geographical latitude in degrees 1 1 50 6 Geographical altitude in meters 1 8...

Page 34: ...n 50 of the minimum load Configure in Setup under Appl Application Appl a tare Minimum Load To tare container weights automatically you need to set a minimum load in the Setup menu under Appl Applicat...

Page 35: ...in 2nd weight unit in this example kg or K Display in 10 fold higher resolution 7 Return to previous display if 10 fold resolution is shown display returns automatically after 5 seconds p 8 Print resu...

Page 36: ...g for the sample L 6 Toggle to the previous display p 7 Print the results G 2 250 kg T 0 000 kg PT2 0 250 kg N 2 000 kg Example Tare the scale by placing a container on the weighing platform e 1 Swit...

Page 37: ...ait until a zero value is displayedtogetherwiththe NET symbol net weight 4 Place packaged sample in the container 2nd tare value 250 5 Enter the tare weight of the packaging in the current weight unit...

Page 38: ...l External adjustment is blocked in legal metrology switch cover is sealed External adjustment only possible by removing the seal If the seal is broken the validity of verification will become void a...

Page 39: ...ibrated In the Setup menu Setup wp 1 1 10 If parameter 1 10 1 is selected in Setup the scale is adjusted automati cally In the Setup menu Setup wp 1 1 10 If parameter 1 10 2 is selected in Setup the i...

Page 40: ...Calibration with automatic adjustment 1 10 2 Calibration with manual adjustment 1 11 Zeroing range 1 11 1 1 percent max cap 1 11 2 2 percent max cap 1 12 Initial zero point range 1 12 1 Factory setti...

Page 41: ...displayed with plus minus signs Ext calibration A printout will be generated if Targ 10000 g the process is cancelled using Diff 1 g the key J 4 Activate calibration adjust ment press the key to cance...

Page 42: ...guidelines of your QA system These settings cannot be changed by the user He or she will document this setting via a Weighing module test as per USP certificate in which the measurements and min sampl...

Page 43: ...enter settings as above 2 Place the container for the sample on the scale and tare 3 Measure the weight of a sample Place the sample on the scale here If the minimum sample quantity has not been reach...

Page 44: ...d Enter ID code names in Setup under setup prtprot 7 4 The name can have a max of 20 characters No more than 11 characters are displayed during input all 20 characters are printed Enter up to 40 chara...

Page 45: ...key Example Enter ID code names For ID codes 1 and 2 enter Batch no and Cust as names e 1 Turn on the device 2 While all segments are lit press the key The first item in the main menu is shownAPPL k 3...

Page 46: ...vorhergehende Inhalt in der Anzeige Mit Signum 2 und 3 k nnen W gewer te von zwei Plattformen erfasst werden Applikationen Anwendungsprogram me zur Verrechnung und Darstellung der W gewerte eingesetzt...

Page 47: ...ction 1 If you store a tare weight value by pressing the key you can later enter a tare value manually The tare value you enter is added to the stored tare value Setting menu code 3 25 1 factory setti...

Page 48: ...ct increased stability the value saved for average piece weight will be more accurate and the results more reproducible but the response time of the weighing platform might be longer Accuracy of Avera...

Page 49: ...e count is less than 1000 Referenzst ck zahl alt Aufgelegte St ckzahl Bereich f r St ck gewichtsoptimierung n n 2 2 n 5 The internally calculated piece count such as 17 24 pcs differs by less than 0 3...

Page 50: ...the reference quantity in this example 20 pcs 20 4 Enter the number of parts using the keypad or using r 1 2 5 10 20 etc r 5 Start calculation of the reference sample weight Set the number of referenc...

Page 51: ...Configured in Setup under Appl def app 9 1 In order to calculate the length surface or volume of a given sample the average weight of a reference quantity of the sample must be known in the example be...

Page 52: ...ccuracy x 100 and so on up to the maximum resolution available Decimal Places in Displayed Result In neutral measurement not only whole numbers but also decimal numbers for example 1 25 o electrical c...

Page 53: ...ction is enabled you do not need to press the key to tare the platform the tare weight is saved automatically when you place the container on the platform 248 3 Enter the weight of 1 meter of cable us...

Page 54: ...rent functions to the c key for deleting applications When you clear applications you can delete either the data stored for all applications or just selected data stored for the active application Con...

Page 55: ...onfigured in Setup under appl a tare 3 5 You can choose from the following 10 levels for this setting 1 digit 2 digits 5 digits 10 digits 20 digits 50 digits 100 digits 200 digits 500 digits 1000 digi...

Page 56: ...perations using the keypad in this example 20 measurements r 4 Save the value entered and begin averaging The averaging routine does not begin until the fluctuation in weight value remains below a def...

Page 57: ...up under appl def app 9 1 To determine the weight of a sample relative to a reference weight you need to define the reference percentage value There are three ways to enter this value in the applicati...

Page 58: ...l places increases display accuracy x 100 and so on up to the maximum resolution available Display of Results With the Weighing in Percent application the result can be displayed as a remainder or los...

Page 59: ...e tare weight is saved automatically when you place the container on the platform 3 Add reference material in accordance with reference percentage in this example 85 g O 4 Begin calculation of referen...

Page 60: ...he active application Configured in Setup under Appl sel cf 3 24 Sel CF function key c in applications Tare function 1 If you store a tare weight value by pressing the key you can later enter a tare v...

Page 61: ...tolerance limit Digital I O Interface The Checkweighing application supports the digital input output interface There are 4 control lines or outputs which are activated as follows see also the diagram...

Page 62: ...1240 g O 5 Save value for the lower limit 1280 6 Enter value for the upper limit in this example 1280 g O Save the value for the upper limit 7 Weigh samples p 8 Printing results Note If automatic pri...

Page 63: ...value for lower limit in this example 1240 g O 5 Save value for the lower limit 1280 6 Enter value for the upper limit in this example 1280 g O Save the value for the upper limit 7 Weigh samples p 8 P...

Page 64: ...sification The lower limit of Class 1 is defined by the preset minimum load The other classes are configured by defining their upper limits There are two ways to enter the delimiters for classes 1 thr...

Page 65: ...hown as either a weight value or a class number Weight display The current weight is shown in the measured value line and the current class in the text line Display of classes The current class is sho...

Page 66: ...s 1 using the keypad in this example 110 g O 3 Save the upper limit for Class 1 130 4 Enter the upper limit for Class 2 using the keypad in this example 130 g O 5 Save the upper limit for Class 2 6 Pl...

Page 67: ...ing menu code 3 25 1 factory setting 2 A tare value entered manually overwrites a stored tare value weight value If you enter a tare value manually a tare value weight value stored later overwrites th...

Page 68: ...automatic taring of the container weight on the platform first weight is configured in Setup under Appl m weigh 3 5 The minimum amount that a component must weigh before it can be saved in totalizing...

Page 69: ...displayed O 2 Store first weight value in totalizing memory G 0 250 kg Component weight is printed T 0 000 kg automatically configured N 0 250 kg component log n 1 The transaction counter value is inc...

Page 70: ...for 1 second after it is saved then the platform is tared Additive mode Display the weight of all components on the platform after it is saved the net weight of the last componentaddedisdisplayedbrief...

Page 71: ...ting Save the settings with the key and exit Setup Press the key several times Minimum Load The minimum amount that a component must weigh before it can be saved in net total memory is configured in S...

Page 72: ...nu line items of your choice 1 Place empty container on the platform 2 Tare the scale Note If the automatic tare function is enabled you do not need to press the key to tare the platform the tare weig...

Page 73: ...w 7 Toggle to the additive mode to display the total weight of all components The value displayed equals the weight of components added up to now plus the current weight on the platform 8 Add the thir...

Page 74: ...Application 3 Totalizing Source of data Application 2 3 22 2 Setup Printout PRT PROT 7 8 Printer 1 Total Print printout when FN pressed then select the menu line items of your choice x xx x e 1 Switch...

Page 75: ...nimum and maximum in this example target 100 pieces minimum 100 pieces maximum 102 pieces O 100 O 102 O D 10 Toggle to Totalizing 11 Add desired number of pieces The number of pieces is saved automati...

Page 76: ...e YDP04IS setting Label manual form feed ISO GLP GMP compliant printout The Setup menu configuration under ISO GMP compliant printout is also active for configured printouts Preparation Turn scale on...

Page 77: ...ey to go to the selection list First printout list of selection list 5 Press the key to add the displayed print item from the selection list to the list of print items Or k 6 Press the k key to go to...

Page 78: ...Press the R key to display the first memory number Press the k key to scroll through in lexical order e g 1 3 333 4 Press the R key to activate the selected memory number Display the saved product val...

Page 79: ...nterface Serial interface Interface operating mode full duplex RS485 half duplex Level RS232 RS485 RS422 Transmission rate 150 300 600 1200 2400 4800 9600 and 19200 baud Parity Space uneven even witho...

Page 80: ...in O Pin Assignment Chart RS485 COM1 female connectors Round socket with screw lock hardware for model SIWXSDC SIWXSBB Front view COM1 pin assignments Round plug 14 pin Pin A Pin B Pin C Pin D Control...

Page 81: ...hing mode 2 M Weighing mode 3 N Weighing mode 4 O Lock keys P Send display value to data interface R Release keys T Taring and zeroing Combined Tare function f3_ Zero see also the kZE_ command f4_ Tar...

Page 82: ...load in checkweighing L Underweight LL Underweight in checkweighing C Adjustment Error Message Pos 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 E r r CR LF or E r r CR LF Space Error code number 2 or 3 digi...

Page 83: ...of 1255 7 g Pos 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 G 1 2 5 5 7 g CR LF Positions 1 6 ID code right justified with spaces Position 7 Plus or minus or space Position 8 Space Positi...

Page 84: ...e display update frequency depends on both the scale model and the operating status Examples N 153 00 g Net weight Stat Display blank Stat L Display underweight Stat H Display overload Data output set...

Page 85: ...ed after the GMP header is printed and remains in the display until the GMP footer is printed A GMP compliant printout is generated automatically at the conclusion of calibration adjustment linearizat...

Page 86: ...74 None Inf 98 Contact your local Service Center Inf 99 Contact your local Service Center NO WP Contact your local Service Center Flashing Setting the time Inf 54 L The load plate is not on the weighi...

Page 87: ...inebea Intec Service Center Maintenance and repair work may be performed only by authorized service technicians who have access to the required maintenance manuals and instructions and who have partic...

Page 88: ...e of the hazardous area only or YPS02 X or YPSC01 X respectively also for installation within the hazardous areas of the zones 1 and 21 100 240 V AC 10 50 60 Hz battery operation via external recharge...

Page 89: ...rifiable verified models Type EC type approval no Weighing capacity kg Readability g Verification scale interval e g Resolution code Calibration weight value in grams Accuracy class not SIWXSBBS For a...

Page 90: ...e EC type approval no Weighing capacity kg Readability g Verification scale interval e g Resolution code Calibration weight value in grams Accuracy class For all models Preload kg 5 5 Repeatability g...

Page 91: ...5 168 SIWXSDCP 99 Abmessungen Ma skizzen Alle Ma angaben in Millimeter 415 2 45 132 5 10 240 350 95 165 55 168 Standard Version Mit integriertem Akku 192 80 237 5 5 260 7 30 41 5 31 150 5 453 5 25 148...

Page 92: ...ns Scale Drawings All dimensions are given in millimeters 45 ca 500 5 ca 237 14 152 205 2 206 35 85 5 146 5 165 2 45 ca 500 5 ca 237 14 152 205 2 182 194 206 35 85 90 116 121 182 194 23 SIWXSBBP 620g...

Page 93: ...93 Signum 3 Ex Dimensions Scale Drawings All dimensions are given in millimeters 93 5 ca 456 ca 45 250 279 158 182 34 5 215 182 5 123 5 117 205 SIWXSBBS Dimensions...

Page 94: ...EX Zone 20 1 21 2 22 Safe Area YP YPSC01 X Associated Intr to connect to ATEX FM Class I II III Div 1 2 Safe Area YP YPS02 XUR AIS to connect CSA Class I II III Div 1 2 FM CSA YPS02 XKR ATEX Zone 20 1...

Page 95: ...C02 Minebea Intec GMP Connect YSW03 0001 Minebea Intec OPC Server 6289OPC Configuration FM FM class 1 safe area Configuration ATEX ATEX zone 1 21 safe area Page 18 Configuration Example Signum 3 Ex Su...

Page 96: ...ng instrument is to be carried out by Minebea Intec please request this service from a customer service employee Re verification in Germany Scale verification for legal metrology is valid until the en...

Page 97: ...97 Signum 3 Ex 97 Declaration of Conformity...

Page 98: ...98 Signum 3 Ex Declaration of Conformity...

Page 99: ...99 Signum 3 Ex 99 Certificates 2017 11 23...

Page 100: ...100 Signum 3 Ex Certificates...

Page 101: ...101 Signum 3 Ex Certificates...

Page 102: ...102 Signum 3 Ex Certificates...

Page 103: ...the following maximum values Ui 12 4 V 12 0 V 7 2V Ii 130 mA 164 mA Any resistively limited Pi any Ci 0 23 F Li 0 mH Uo 5 2 V Io 210 mA Po 263mW Co 60 F Lo 0 6 mH Lo Ro RS422 circuit Data Interface C...

Page 104: ...104 Signum 3 Ex Certificates...

Page 105: ...nF Li 0 0 mH V_2 pin 1 and 4 Ui 12 6 V Ii 133 mA Pi 1 46 W Ci 3 nF Li 0 0 mH V_3 pin 5 and 8 Ui 8 6 V Ii 187 mA Pi 1 51 W Ci 391 nF Li 0 0 mH V_4 pin 3 and 7 Ui 12 6 V Ii 150 mA Pi 1 68 W Ci 223 nF Li...

Page 106: ...G F E D O in type of protection intrinsic safety Ex ib IIC or Ex ib IIIC only for connection to a certified intrinsically safe circuit with the following maximum values Ui 8 6 V Ii any Pi any Ci 0 nF...

Page 107: ...g Unit SIWXSBBP 3 06 Hhi Weighing Unit SIWXSBBP 3 V1lm Weighing Unit ISXBBP 3 06 Hhi Weighing Unit ISXabc V1lm Weighing Unit 4 Name of Listing Company Minebea Intec Bovenden GmbH Co KG 5 Address of Li...

Page 108: ...one 21 AEx ib Group IIIC in accordance with Control Drawing 36953 751 07 T80 C Hazardous Indoor Classified Locations over a temperature range of 10 C to 40 C SIWXSBBP 3 06 Hhi Weighing Unit SIWXSBBP 3...

Page 109: ...in an ambient temperature range of 10 C to 40 C The maximum surface temperature for dusts of the SIWXSabc d ef ghi Weighing Unit and the ISXabc ef ghi Weighing Unit is 80 C 13 Specific Conditions of U...

Page 110: ...WXSBBP 3 06 Hhi Weighing Unit SIWXSBBP 3 V1lm Weighing Unit ISXBBP 3 06 Hhi Weighing Unit ISXabc V1lm Weighing Unit 4 Name of Listing Company Minebea Intec Bovenden GmbH Co KG 5 Address of Listing Com...

Page 111: ...hing Unit ISXBBP 3 06 Hhi Weighing Unit ISXabc V1lm Weighing Unit IP4X Models SIWXSBBP 3 06 H SIWXSBBP 3 V1lm Scale and ISXBBP 3 06 H ISXabc V1lm Weighing platform as Intrinsically Safe for use in Cla...

Page 112: ...ectrostatic charging of the equipment shall be avoided clean only with a damp cloth 14 Test and Assessment Procedure and Conditions This Certificate has been issued in accordance with FM Approvals Can...

Page 113: ...113 Signum 3 Ex...

Page 114: ...8 Non Hazardous Location Hazardous Classified Location Class I II III Division 1 Groups A B C D E F G Canada Group A is excluded Power 2 3 SARTORIUS Power Supply Type YPS02 XKR 16 Hazardous Classified...

Page 115: ...i RS232 12 6 V 25 2 V 328 mA any 2 2 nF 0 5nF 0 mH RS422 8 6 V 210 mA 0 5 W 0 5 F 0 mH RS485 see below see below any 260 nF 0 mH Digital I Os 8 6 V any any 0 F 0 mH versus ground between the lines res...

Page 116: ...resp Uo Io Po of the associated apparatus are less than or equal to Vmax Imax and Pmax resp Ui Ii Pi of the intrinsically safe apparatus and the approved values of Ca and La resp Co and Lo of the asso...

Page 117: ...117 Signum 3 Ex Verification of intrinsic safety...

Page 118: ...118 Signum 3 Ex Verification of intrinsic safety...

Page 119: ...119 Signum 3 Ex Verification of intrinsic safety...

Page 120: ...120 Signum 3 Ex Verification of intrinsic safety...

Page 121: ...121 Signum 3 Ex Verification of intrinsic safety...

Page 122: ...122 Signum 3 Ex Verification of intrinsic safety...

Page 123: ...123 Signum 3 Ex Verification of intrinsic safety...

Page 124: ...124 Signum 3 Ex 124...

Page 125: ...4 LV2 or Important note Max voltage Vm of any electrical apparatus connected to the interface converter type YDI05 Z may not exceed 250V The internal Zener voltage Vz is 12 6V Note 1 External power su...

Page 126: ...CC01 09ISM5 25 contact RS 232 connection to PC instead of YCC01 03ISM5 9 contact female connector Option M57 cable 65710 809 00 3 m 9 contact RS 232 connection to YDP04IS 0CE printer instead of 69Y031...

Page 127: ...12V DC min to 30V DC max 1 12 contact 1 6 LV1 B H E 12 contact 4 2 5 LV1 TxD CTS DTR CTS C B violet 5 6 black DTR CTS D 3 DTR RxD TxD G M pink 7 8 gray RxD TxD C 1 RxD 10 1 or Signal_GND 1 LV4 or DC...

Page 128: ...C instead of YCC01 03ISM5 Option M57 cable 65710 809 00 3 m 9 contact RS 232 connection to YDP04IS 0CE printer instead of 69Y03142 YDI05 Z Connection options for scale interface RS 422 Option M54 cabl...

Page 129: ...ecessary a terminating resistor 470R 1 0 6W may be soldered between Pin J and K of the connector Junction Box e g 72583 LV4 2 3 1 LV4 1 10 Cable gland SIWXS 3 or ISX Option A13 RS485 14 contact M J K...

Page 130: ...nal GND M G E F O D Digital IOs Intrinsically safe device Hazardous area YCC02 XR14M6 connecting cable Option of CIXS3 CX3S CHX3 Option of CIXS3 CX3S CHX3 Interface can be selected and configured by s...

Page 131: ...ac YPS02 XV24 EX Power Supply 24 Vdc YRB02 X EX Rechargeable Battery Pack YPS02 Z R EX Power Supply 100 240 Vac YPS02 XV24 EX Power Supply 24 Vdc 3m 2m 20m 5m 5m 5m 5m 3m 3m YPSC01 X EX Power Supply 1...

Page 132: ...pment operator is obligated to connect a lead with a gauge of at least 4 mm cross section to the PA terminal located on the side of the housing The low resistance of this connection to the PA busbar m...

Page 133: ...in ascending order 0 9 or the p key numbers in descending order 9 1 until the required character appears on the display If the password is longer than 7 characters the first character will be displac...

Page 134: ...134 Signum 3 Ex...

Page 135: ...135 Signum 3 Ex...

Page 136: ...hout prior written permission from Minebea Intec All rights reserved by Minebea Intec in accordance with copyright law The information and figures contained in these instructions correspond to the ver...