9. Fieldbus interface | 9.2 - Scale protocol | 126
Output range (MISO)
Byte
Value
Description
0
00
Gross weight - byte 0 (MSB)
1
00
Gross weight - byte 1
2
04
Gross weight - byte 2
3
D2
Gross weight - byte 3 (LSB)
4
08
Gross weight request de
tected.
5
Write
Ac
tive
Pow
er
Fail
6
Cmd
Busy
Cmd
Error
Tare
Ac
tive
Cal
Chan
ged
Test
Ac
tive
7
Out
Of
range
Stand
still
In
side
ZSR
Cen
ter
Zero
Be
low
Zero
Over
load
Above
Max
ADC
Error
In direct access, status bits
are independent of the
write or read request.
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
The gross value (hex:000004D2 <=> 1234) can be read from bytes 0–3.
Negative values are output in the second complement.