background image

 

 

 

 

 

 

 

 

 

 

 

 

 

Digital Ultrasound Diagnostic 

System 

DICOM Quick Guide 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for DICOM

Page 1: ...Digital Ultrasound Diagnostic System DICOM Quick Guide...

Page 2: ...Intellectual Property Statement 2009 2011 Shenzhen Mindray Bio medical Electronics Co Ltd All Rights Reserved...

Page 3: ...eve 28 2 8 Structured Report SR 29 2 8 1 Attach SR When Storage Images 29 2 8 2 Only Store SR 30 2 9 DICOM Media Storage and Review 30 2 9 1 DICOM Media Storage 31 2 9 2 DICOMDIR Review 31 2 10 Task M...

Page 4: ...ut retrieve is failed with the prompting that the remote server is wrong 36 3 11 Common Failure Error messages in DICOM Task Management 37 3 11 1 Association aborts 37 3 11 2 Network error Socket send...

Page 5: ...s the following DICOM functions Verify Connectivity Storage DICOM Print DICOM Worklist MPPS Modality Performed Procedure Step Storage Commitment Q R DICOM Medium Storage DICOMDIR Review DICOM Task Man...

Page 6: ...creen Local TCP IP preset items are described as follows Name Description Station name Name of the ultrasound system Station Location Location or department where the system is placed DHCP Static DHCP...

Page 7: ...to 65536 if the value is less than 16384 or greater than 65536 the system automatically sets it to the value 32768 File Name System default can t be set The user can review log content in D Product n...

Page 8: ...Name Description Device Name of the device supporting DICOM services IP Address IP address of the server Ping Check whether IP Address can connect normally or not Add Click to add server s to the Devi...

Page 9: ...d as below Name Description Devices After you set the server s in DICOM Server screen the name s will appear in the drop down list select the name of the storage server Service name Default is xxx Sto...

Page 10: ...e images sent from system to server will be coded by 8bit The images will contain DICOM tags window center 0028 1050 and window width 0028 1051 if they are coded by 8bit The default is Color Allow Mul...

Page 11: ...pplication Entity title here it should be consistent with that of the print server Port DICOM communication port 104 is default Here the port should be consistent with that of the print server port Ma...

Page 12: ...on Type Select how the printer magnifies an image to fit the film Replicate interpolated pixels belong to duplicate of adjacent pixels Bilinear interpolated pixels are generated from bilinear interpol...

Page 13: ...y it 1 4 3 Worklist Preset Figure 6 DICOM Worklist Preset Screen The main parameters of DICOM Worklist are described as below Name Description Devices After you set the server s in DICOM Server screen...

Page 14: ...ers in the above area and click Update to update the item in the service list Delete Click to delete the selected service in the service list Verify Click to verify if the two DICOM application entiti...

Page 15: ...ort DICOM communication port 104 is default Here the port should be consistent with that of the MPPS server port Maximum Retries 0 9 times are optional the default is 3 Reserved Interval Time Sec 5 18...

Page 16: ...rs of storage commitment are described as below Name Description Devices After you set the server s in DICOM Server Preset screen the name s will appear in the drop down list select the name of the se...

Page 17: ...Click to cancel parameter preset Update Select an item in the service list change the parameters in the above area and click Update to update the item in the service list Delete Click to delete the s...

Page 18: ...ximum Retries 0 9 times are optional the default is 3 Reserved Interval Time 5 1800 seconds 15 seconds is default Reserved Timeout Value 5 60s in increments of 5s and 15 is default After user sending...

Page 19: ...clude Patient information management iStation Review status Review Real time Freeze status auto workflow Thumbnail area in main screen DICOM storage supports Single file transfer Exam transfer Batch t...

Page 20: ...ne or more exam records that contain images If not the system will prompt in exam list or select one or more images in an exam as shown in Figure 10 iStation Screen Figure 10 iStation Screen 4 Click S...

Page 21: ...is sending result in prompt dialog box as shown in Figure 12 Figure 12 Task Management 2 2 2 Send to DICOM Storage Automatically Function paths of sending image to DICOM storage and sending images by...

Page 22: ...ult storage server one or more 3 When pressing End Exam with the current exam being active all images and SR of the current exam are sent to the default DICOM storage server B Send to DICOM Storage wh...

Page 23: ...image the system will save and send a single frame image to remote DICOM storage when Save is pressed If Save on control panel is preset as saving multi frame image the system will save and send a mul...

Page 24: ...e system will save and send a multi frame image to remote DICOM storage When the system is connected to external storage media it allows saving the image as DCM format The detailed operations are as f...

Page 25: ...storage configuration of this server in Storage screen in the system Select the service and select Uncompressed and then click Update to update the latest configuration information Failure The net is...

Page 26: ...m Multiple files in one exam will be sent in one DICOM connection The auto send function can be triggered by Presettable Ending the exam send to default print service Saving an image by pressing the u...

Page 27: ...server 3 If Save on control panel is preset as saving single frame image the system will save and send a single frame image to remote DICOM printer when Save is pressed Send to DICOM print when pressi...

Page 28: ...f the system time The default Modality type is US user also can input the value and System will record the value automatically Patient records will be listed after clicking Query Figure 18 Query in Wo...

Page 29: ...screen if a default WorkList Server is set Check the DICOM preset and network connection if a query error occurs 2 5 MPPS MPPS is to send the states information of exams to the configured server Thus...

Page 30: ...ts are sent to the commitment server automatically 3 The state of the committed service will be returned with the column in iStation screen marked with a tick if the commitment is succeeded Otherwise...

Page 31: ...an be sent along with an exam record that has image s saved The type of SR to be sent is determined by the application region of the exam Send obstetric SR gynecology and obstetrics exam Send cardiac...

Page 32: ...data patient and image information into the media USB flash drive optical disk or removable hard disk DICOM media review DICOMDIR function supports viewing DCM image s stored in external media Prerequ...

Page 33: ...he media otherwise the media storage process will be failed due to insufficient space 2 9 2 DICOMDIR Review Steps 1 Press iStation on the control panel to enter the patient information screen 2 Select...

Page 34: ...iagnostic Ultrasound System 32 1 Task in progress the icon indicates in green 2 No task is in progress with failed task exists the icon indicates in yellow 3 No task is in progress without failed task...

Page 35: ...ated on the server check the server setting if the verification service is activated Troubleshooting Check the networks normally Check the DICOM Conformance Statement if the SCP is supported Enable th...

Page 36: ...ent or settings of the server 3 3 Common Failure Network disconnected shown by network icon during transmission Potential Reasons The network cable is disconnected during transmission The connected sw...

Page 37: ...the printer can support color printing if not modify the Settings in DICOM Service Print to B W type MONOCHROME2 Generally the Medium Type is set to Blue File for B W printing while Paper or Clear Fi...

Page 38: ...is set 3 The port and IP address settings on the commitment server are inconsistent with the local preset Troubleshooting 1 Check if the associated storage commitment server is correct 2 Check if a d...

Page 39: ...COM Local Preset 3 11 Common Failure Error messages in DICOM Task Management 3 11 1 Association aborts Potential Reasons The association is denied by the SCP due to incorrect setting of AE_TITLE on th...

Page 40: ...1 Printer settings on local ultrasound system should consist with that specified on printer conformance statement 2 The operations being performed are supported by the printer The following are two ex...

Page 41: ...a type and size as follows For grayscale images uses the media set for Grayscale in the Default Media menu at the control panel For color images uses the media set for Color in the Default Media menu...

Page 42: ...ority medium Sets print job priority to medium priority low Sets print job priority to low receive 1 Forces sheet output to receive tray 1 receive 2 Forces sheet output to receive tray 2 receive 3 For...

Page 43: ...ME2 for B W printing 2 Medium Type Blue Film Incorrect Paper and Clear file are supported by color printer according to the printer conformance statement but only Paper is available as displayed in th...

Page 44: ...FORMAT STANDARD 3 5 5 Film Orientation Portrait Result succeeded Reasons Settings of Film orientation along with the FORMAT that supported by FUJIFilm drypix4000 printer are specified in the conforman...

Page 45: ...ANDARD 2 4 STANDARD 3 3 STANDARD 3 4 STANDARD 3 5 STANDARD 3 6 STANDARD 4 4 STANDARD 4 5 STANDARD 4 6 STANDARD 4 7 STANDARD 4 8 STANDARD 5 5 STANDARD 5 6 STANDARD 5 7 STANDARD 5 8 STANDARD 6 6 STANDAR...

Page 46: ...TANDARD 4 2 STANDARD 3 3 STANDARD 4 3 STANDARD 5 3 STANDARD 6 3 STANDARD 4 4 STANDARD 5 4 STANDARD 6 4 STANDARD 7 4 STANDARD 8 4 STANDARD 5 5 STANDARD 6 5 STANDARD 7 5 STANDARD 8 5 STANDARD 6 6 STANDA...

Page 47: ...mindray DC7 Diagnostic Ultrasound System Shenzhen Mindray Bio medical Electronics Co Ltd P N 046 000635 00 V5 0...

Reviews: