22
Operation
Inhibit terminals
Shorting the inhibit terminals (SO501) to each other causes the
motor to either coast to a stop or brake to a stop. First set the
inhibit personality to coasting or braking to a stop (see Inhibit
personality on page 14). Next, short the inhibit pins to coast or
brake to a stop. Remove the short to accelerate the motor to set
speed.
Minarik Corporation offers two accessory plug harnesses for use
with the Inhibit terminals:
Table 2. Inhibit Plug Harness Assembly Part Number
Minarik
Part Number
Description
201-0024
Inhibit plug with 18 in. (46 cm) wires
201-0079
Inhibit plug with 36 in. (91 cm) wires
Twist inhibit plug wires and separate them from other power-
carrying wires or sources of electrical noise. Use shielded cable if
the inhibit plug wires are longer than 12 inches (30 cm). If
shielded cable is used, ground only one end of the shield to earth
ground. Do not ground both ends of the shield.
250-0246r2_readers.qxd 6/7/01 10:51 AM Page 22
Summary of Contents for NRG-2Q Series
Page 1: ...User s Manual NRG 2Q Series Two Quadrant Regenerative PWM Drives for DC Brush Motors...
Page 12: ...6 Regenerative Drives Figure 2 Two Quadrant Operation...
Page 19: ...13 Installation Also see Dynamic brake resistor sizing page 23 Figure 3 NRG 2Q Connections...
Page 31: ...25 Operation Figure 7 Dynamic Braking Circuit Connection...
Page 57: ...Notes...
Page 58: ...Notes...