DECEL
The DECEL setting determines the time the motor takes to ramp
to a lower speed. DECEL is factory set for the fastest deceleration
time (full CCW).
To calibrate DECEL:
1. Set the speed adjust potentiometer or voltage input signal to
maximum forward speed. The motor should run at maximum
speed.
2. Set the speed adjust potentiometer or voltage input signal to
minimum speed and measure the time it takes the motor to go
from maximum to minimum speed.
3. If the time measured in step 2 is not the desired deceleration
time, turn the DECEL trimpot CW for a slower deceleration
time, or CCW for a faster deceleration time. Repeat steps 1
through 3 until the deceleration time is correct.
33
Calibration
250-0246r2_readers.qxd 6/7/01 10:51 AM Page 33