background image

6

CHARGER OPERATION

WARNING

Charge only MILWAUKEE M12™ 

Lithium-Ion  battery  packs  in  the 

MILWAUKEE Li-Ion Battery Charger. Other types 

of batteries may cause personal injury and dam

-

age. Battery pack and charger are not compatible 

with V™-technology or NiCd systems.

When to Charge MILWAUKEE Li-Ion 

Battery Packs

Remove the battery pack from the tool for charging 

when convenient for you and your job. MILWAUKEE 

batteries do not develop a "memory" when charged 

after only a partial discharge. It is not necessary to run 

down the battery pack before placing it on the charger. 

• Use the Fuel Gauge to determine when to charge 

your MILWAUKEE Li-Ion battery pack. 

• You can "Top-Off" your battery pack's charge before 

starting a big job or long day of use. 

How to Charge the Battery Pack

Plug the Radio + Charger into a 120V outlet. The 

battery packs will not charge if the Radio + Charger 

is not plugged in. Place the battery pack onto the bay 

by sliding the pack on from the top of the bay. The 

red light will turn on, either flashing (pack is too hot 

or cold) or continuous (pack is charging). 

• 

A fully discharged battery pack with an internal tem

-

perature in the normal range will charge in about 30 

to 185 minutes, depending on the battery pack. 

• Heavily cycled batteries may take longer to charge 

completely. 

• The  Fuel  Gauge  lights  on  the  battery  pack  are 

displayed as the pack is being charged, indicating 

how fully charged the pack is. 

• After charging is complete, the continuous green 

light will turn on and the fuel gauge will turn off.

• The charger will keep the battery pack fully charged 

if it is left on the charger.

• If the light indicator flashes red and green, check 

that the battery pack is fully seated into the bay. Re

-

move the pack and reinsert. If the problem persists, 

contact a MILWAUKEE service facility.

• If the light indicator does not come on, check that 

the battery pack is fully seated into the bay. Remove 

the pack and reinsert. If the light indicator still does 

not come on, contact a MILWAUKEE service facility.

Charging a Hot or Cold Battery Pack

The Red Flashing Indicator light on the charger in

-

dicates that the battery pack temperature is outside 

the charging range. Once the battery pack is within 

the acceptable range, normal charging will take place 

and the red light will be continuous. Hot or cold bat

-

teries may take longer to charge.

Li-Ion Charging Status

Battery Pack 

Temperature

Red Charger 

Indicator Light

Charging Status

Too Hot

Normal Range

Too Cold

Fast Flashing

Continuous

Fast Flashing

Not charging

Normal charging

Not charging

MAINTENANCE

WARNING

To reduce the risk of injury, always 

unplug the charger and remove the 

battery  pack  from  the  charger  or  tool  before 

performing any maintenance. Never disassemble 

the  tool,  battery  pack  or  charger.  Contact  a 

MILWAUKEE service facility for ALL repairs.

Maintenance and Storage

Store your charger in a cool, dry place. 

As a general practice, it is best to unplug battery 

chargers and remove battery packs when not in use. 

No battery pack damage will occur, however, if the 

charger and battery pack are left plugged in.

Changing Back-up Batteries

WARNING

Batteries may leak chemicals or 

may explode if  used incorrectly.  

The following care should be taken to prevent 

such an incident:

•Make sure the positive (+) and negative (-) bat

-

tery terminals are positioned correctly.

•Do not mix new and old batteries together, or 

mix different types of batteries.

•Do not try to recharge non-rechargeable batteries. 

If chemicals from the batteries come in contact 

with your skin, wash them off immediately with 

water. If chemicals leak onto the radio, clean the 

radio completely.

Choking  hazard.  Keep  batteries  away  from 

children.

To hold station presets and clock time when the bat

-

tery pack is removed and the radio is unplugged, (2) 

AAA batteries are required.

1. Remove battery pack and unplug radio.

2. Remove the screw and battery cover located 

near the battery bay.

3. Insert two (2) AAA batteries according to 

matching positive (+) and negative (-) marks.

4. Replace the battery cover and screw.

5. Always dispose of used batteries properly.

WARNING

To reduce the risk of fire, personal 

injury, and product damage due to 

a short circuit, never immerse your tool, battery 

pack or charger in fluid or allow a fluid to flow 

inside them. Corrosive or conductive fluids, such 

as seawater, certain industrial chemicals, and 

bleach or bleach containing products, etc., can 

cause a short circuit.

Cleaning

Clean out dust and debris from charger vents and 

electrical contacts by blowing with compressed air. 

Use only mild soap and a damp cloth to clean the 

battery pack and charger, keeping away from all elec

-

trical contacts. Certain cleaning agents and solvents 

are  harmful  to  plastics  and  other  insulated  parts. 

Some of these include gasoline, turpentine, lacquer 

thinner, paint thinner, chlorinated cleaning solvents, 

ammonia and household detergents containing am

-

monia. Never use flammable or combustible solvents 

around battery packs, charger, or tools. 

Repairs

For repairs, return the tool, battery pack and charger 

to the nearest service center.

Summary of Contents for M12 2951-20

Page 1: ...sk of injury user must read and understand operator s manual AVERTISSEMENT Afin de r duire le risque de blessures l utilisateur doit lire et bien comprendre le manuel ADVERTENCIAPara reducir el riesgo...

Page 2: ...al objects that can make a connection from one terminal to another Shorting the battery terminals together may cause sparks burns or a fire 21 Avoid body contact with grounded surfaces such as pipes r...

Page 3: ...ouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the eq...

Page 4: ...C Volts 120 AC Input AC Amps 0 8 A Input DC Volts 14 DC Input DC Amps 2 3 A Output Volts 12 DC Output Amps 1 0 A Battery Type M12 Charger Type M12 Recommended Operating Temperature Battery and Charger...

Page 5: ...unning on battery power the display will dim after 5 minutes to reduce power use Use the Volume up and down buttons to increase or decrease the volume Setting the Clock 1 Press and hold the CLOCK butt...

Page 6: ...arging Status Too Hot Normal Range Too Cold Fast Flashing Continuous Fast Flashing Not charging Normal charging Not charging MAINTENANCE WARNING To reduce the risk of injury always unplug the charger...

Page 7: ...period if no proof of pur chase is provided at the time warranty service is requested ACCEPTANCE OF THE EXCLUSIVE REPAIR AND REPLACEMENT REMEDIES DESCRIBED HEREIN IS A CONDITION OF THE CON TRACT FOR T...

Page 8: ...doivent tre recharg s qu avec le chargeur sp cifi Un chargeur ap propri pour un type de piles peut cr er un risque d incendie s il est utilis avec un autre type de piles 19 Utiliser exclusivement les...

Page 9: ...t expos directement la lumi re du soleil un v hicule ou une construction en m tal pendant l t Federal Communications Commission AVERTISSEMENT Toute modification apport e l unit qui n a pas t express m...

Page 10: ...s sont dot es d un syst me sp cial double isolation qui r pond aux exigences de l OSHA et respecte les normes applicablesdelasoci t Under Fig A Fig B writers Laboratories Inc de l Association canadien...

Page 11: ...ue ceux qui sont expres s ment recommand s pour cet outil peut com porter des risques Afin de r duire le risque de choc lectrique ou d incendie n exposez pas cette radio la pluie ni l humidit Mise en...

Page 12: ...ant glisser depuis le haut du compartiment Levoyantrouges allumeetclignote bloc trop chaud ou trop froid ou est fixe bloc en charge Une batterie compl tement d charg e avec une temp rature interne de...

Page 13: ...arantie ne couvre pas les dommages que MILWAUKEE d termine tre caus s par des r parations ou des tentatives de r paration par quiconque autre que le personnel agr par MILWAUKEE ou par des utilisations...

Page 14: ...A DE C V Miguel de Cervantes Saavedra No 301 Piso 5 Torre Norte 11520 Colonia Ampliaci n Granada Miguel Hidalgo Ciudad de Mexico Mexico Mod le Date d achat Sceau du distributeur ou du magasin INSTRUC...

Page 15: ...l Las bater as se da ar n o quedar n inservibles permanentemente 31 EVITE AMBIENTES PELIGROSOS No cargue la bater a en la lluvia nieve o lugares h medos o mo jados No use la bater a ni el cargador en...

Page 16: ...s de las varias placas y use la suma para determinar el tama o m nimo del cable de extensi n Gu as para el uso de cables de extensi n Si est usando un cable de extensi n en sitios al aire libre aseg r...

Page 17: ...cciones espec ficas sobre c mo cargar lea el manual del operador sumin istrado con su cargador y la bater a Potencia El radio cargador M12 MILWAUKEE puede energizarse con las bater as de ion de litio...

Page 18: ...un dispositivo Bluetooth no est conectado se iniciar autom ticamente el enlazado de Bluetooth y el icono destellar en la pantalla El radio continuar buscando una se al durante 3 minutos Mientras parpa...

Page 19: ...mar ciertos productos qu micos industriales y blan queadores o lej as que contienen etc pueden causar un cortocircuito Limpieza Limpie el polvo y basura de las ventilas del cargador y los contactos e...

Page 20: ...NTO NO SEA PERMITIDO POR LA LEY DICHAS GARANT AS IMPL CITAS SE LIMITAN A LA DURACI N DE LA GARANT A EXPRESA COR RESPONDIENTE SEG N SE DESCRIBI ANTERIORMENTE ALGUNOS ESTADOS NO PERMITEN LIMITACIONES SO...

Reviews: