MIL'S EVISA ATEX E100.R Start-Up And Maintenance Instructions Download Page 17

EVISA ATEX E65.R / E100.R / E200.R / E300.R 

 

517976-04 

15 

 

 

EN
 

 

Shipping 

2.4.

The machines must be correctly packed in their original packaging before shipping. It is preferable to secure 
the  package  to  a  European  pallet  so  that  it  cannot  overturn. 

The  pump  must  be  drained  before  being 

shipped

 

Mounting 

2.5.

The vacuum pumps have four silentblocs with tapped holes in the base: 4xM8 for the E65.R/E100.R models, 
and 4xM10 for the E200.R/E300.R models. 
We recommend that you use these tapped holes to mount the pump on a base frame. 

 

Handling 

2.6.

Use the lifting rings provided for that purpose. Never place slings under the pump. 

 

INSTALLATION AND PUTTING INTO SERVICE 

3.

 

Installation 

3.1.

The suction and discharge ports are  protected during transport by caps or stickers. Remove these covers 
before commissioning the pump. 
Never operate the pump with these guards, as this may destroy the pump. 

 

Suction 

3.1.1.

A flame arrestor is recommended if there is a resolutely probable flame at intake. 
Connect the suction to the process, preferably via a flexible connection, with filters inserted beforehand if 
necessary.  The  flexible  connection  must  withstand  the  final  pressure  (0.05  mbar  absolute).  For  the  pipe 
diameter, at least the connection diameter must be observed. Remember to seal your connections. 
To protect the pump, it is recommended to install an upstream filter or separator connected to the suction. 
This filter  must  be  mounted  on the  pump in such a  way  that  no  solid  or  liquid  particles enter  the  pump 
when replacing the filter element. 
The  pump is equipped with a  non-return check  valve  to  prevent  oil  from  rising  upwards  if  the  enclosure 
upstream of the suction port remains vacuumised when the pump stops. However, this non-return check 
valve  is  not  a  safety  device.  It  is  recommended  to  isolate  the  pump  from  the  vacuum  system  when  it  is 
switched off. Install an automatic isolation valve that closes when the pump stops, or a  non-return check 
valve between pump and enclosure. 

Ground continuity must be ensured between vacuum pump, filtration, customer network and 
flexible connection. Connection pipes can accumulate electrostatic charges. 
Stainless steel hoses are available as an option. 

 

Never operate the vacuum pump with an open suction connection. 

 

Undersized and/or excessively long suction piping reduces pump performance. 

 

The suction pressure must not exceed the atmospheric pressure. 

 
After installation and after any work on the system, carry out a leakage check. 
The  vacuum  line  must  be  sealed,  reactive  or  corrosive  gases  can  escape  through  leaky  areas  where  the 
pumped gases can react with air or moisture. 

 

Exhaust 

3.1.2.

Do  not  reduce  or  close  the  exhaust  opening.  If  the  discharge  is  collected,  the  pipe  section 
must  have  a  minimum  internal  diameter  equivalent  to  that  of  the  pump  discharge  port. 
Pipelines must be dimensioned in such a way that the pressure in the piping connected to the 
discharge never exceeds 100mbar relative. 

 
If  several  pumps  are  connected  to  the  same  exhaust  piping,  the  section  of  the  latter  must  at  least  be 
equivalent to that of the sum of sections of the pumps' discharge ports. The manifold must be designed so 
that,  if  condensation  forms  in  the  exhaust  piping,  it  cannot  return  by  flow  to  one  of  the  pumps.  It  is 
recommended to place a draining system at the lowest point of the discharge piping. 
Use a hose that withstands heat and oil vapour to connect to the pipe. 
If the exhaust is connected to an extraction system, the relative pressure to the pump discharge must not 
drop below -50mbar. 

 

Depending on the application, the gases or vapours released can be harmful to health and/or 
the environment. Respect applicable regulations. 
Protection by insect protection if the discharge is outside. 

 

The discharge of the vacuum pump may, if not collected, create a hazardous area within the 
meaning of Directive 1999/92/EC. 

 

Do not operate the vacuum pump with obstructed exhaust (risk of explosion) 

 

 

Filling of oil 

3.1.3.

Remove the oil plug and fill up to the middle of the oil sight glass at the bottom of the housing. 

Operation without oil or with insufficient oil may damage the vacuum pump. 

 

The  use  of  oil,  other  than  that  recommended by MIL'  S, engages  your responsibility  and/or 
responsibility of your supplier. The use of unsuitable oil can destroy the pump. 

 

 

Electrical connection 

3.1.4.

The  electrical  connection  must  be  carried  out  by  a  qualified  electrician  to  ensure  the 
connection to be carried out correctly and in accordance with the regulations in force in the 
country of use. 

 

If the loss of vacuum can be dangerous to the process in which it is used, the vacuum pump 
and its control system must be connected to a backup power supply. 

 

 

Summary of Contents for EVISA ATEX E100.R

Page 1: ...UND WARTUNGSHANDBUCH MIL S SAS 15 rue de Gen ve 69 746 GENAS Cedex France T l phone 33 0 4 72 78 00 40 T l copie 33 0 4 78 00 82 34 http www mils eu e mail sales mils fr 517976 04 11 2017 EVISA E65 R...

Page 2: ...ion de la soci t MIL S SAS Le non respect de cette clause peut entra ner des poursuites This document may not be forwarded or reproduced without authorisation from MIL S SAS company Failure to respect...

Page 3: ...dommages la machine Rappel particulier la r glementation et ou l application correcte de certaines pr cautions Symbole danger Ce pictogramme repr sente le symbole DIN 4844 avertissement d un danger il...

Page 4: ...plage de fonctionnement de ces pompes s tend de la pression atmosph rique au vide limite de la pompe en continu Ces pompes vide sont pr vues pour fonctionner De la pression atmosph rique au vide limi...

Page 5: ...a directive 2014 34 UE n est fourni par la soci t MIL S Toutefois un coffret standard peut tre ventuellement propos mais devra tre install hors zone ATEX par le client En aucun cas la soci t MIL S n a...

Page 6: ...dans un b ti de machines prendre soin d assurer une ventilation efficace La pompe vide ne fonctionnera correctement que sur une surface horizontale apte supporter la masse totale de la pompe et de se...

Page 7: ...la pompe La pression l aspiration ne doit pas d passer la pression atmosph rique Apr s installation et apr s toute intervention sur l installation proc dez un contr le de fuite La conduite de vide do...

Page 8: ...nde donn e en annexe Pour la gestion de la sonde se r f rer EN80079 37 6 5 Le bon fonctionnement de la sonde de temp rature est test avant exp dition Mise en service 3 2 Avant tout d marrage de la pom...

Page 9: ...r s qui peuvent avoir t expos s des temp ratures sup rieures 260 Ces op rations sont confier du personnel qualifi et habilit Le non respect de la pr conisation du fabricant et de la non utilisation de...

Page 10: ...de la cartouche Remettre en place la plaque 2 avec son nouveau joint Revisser les crous 1 Nombre de cartouches s paratrices E65 R E100 R E200 R E300 R Une Deux Trois Clapet aspiration 3 3 4 Une grill...

Page 11: ...nt de raccordement afin de garantir la continuit de masse Purgeur automatique 3 3 9 Ce purgeur r injecte l huile provenant de la cartouche s paratrice dans la pompe Il se trouve dans le compartiment d...

Page 12: ...tes 2 le d bit de la pompe est trop faible 2 1 Pompe inadapt e l application 2 2 Grille aspiration colmat e 2 3 Filtre aspiration colmat option 2 4 Cartouche s paratrice colmat e 2 5 Tuyauterie trop l...

Page 13: ...ilure to observe this symbol may result in personal injury and possibly damage to the machine A specific reminder is made of the regulations and or proper application of certain precautions Danger sym...

Page 14: ...lute The operating range of these pumps extends from atmospheric pressure to the limit vacuum of the pump in continuous running These vacuum pumps are designed for operation From atmospheric pressure...

Page 15: ...box according to the 2014 34 EU directive However a standard control electrical box can be proposed but must be installed outside the ATEX zone by the customer MIL S company never insures the installa...

Page 16: ...machinery assemblies ensure that ventilation is adequate The vacuum pump will only operate correctly on a horizontal surface capable of supporting the total mass of the pump and its accessories Opera...

Page 17: ...on connection Undersized and or excessively long suction piping reduces pump performance The suction pressure must not exceed the atmospheric pressure After installation and after any work on the syst...

Page 18: ...C When connecting the sensor respect the instructions of the sensor manufacturer given in the appendix For sensor management refer to EN80079 37 6 5 The well functioning of the temperature sensor is...

Page 19: ...luorinated products which may have been exposed to temperatures above 260 C These operations must be carried out by qualified and accredited personnel Failure to comply with the manufacturer s recomme...

Page 20: ...ing cartridges E65 R E100 R E200 R E300 R One Two Three Suction valve 3 3 4 A screen 1 is located at the pump s suction port Depending on the level of impurities sucked up it must be cleaned regularly...

Page 21: ...h through the connection point to ensure ground continuity Automatic drain 3 3 9 This drain reinjects the oil from the separating cartridges into the pump It is located in the separating cartridge com...

Page 22: ...rotated by hand check the vanes 2 The pump flow rate is too low 2 1 Pump inappropriate for the application 2 2 Suction intake screen clogged 2 3 Suction filter optional clogged 2 4 Oil separating cart...

Page 23: ...tuell Maschinensch den verursachen kann Besonderer Hinweis auf die Vorschriften und oder auf die richtige Anwendung bestimmter Vorsichtsma nahmen Gefahrensymbol Dieses Piktogramm stellt das Symbol DIN...

Page 24: ...sse unter Vakuum zu setzen 0 05 mbar Absolut druck Diese Vakuumpumpen sind ausgelegt f r einen Betrieb unter folgenden Bedingungen zwischen Umgebungsdruck bis zur Vakuumgrenze der Pumpe in Dauerbetrie...

Page 25: ...ten elektrischen Steuerschrank im Sinn der Richtlinie 2014 34 EU Ein Standardsteuerschrank kann eventuell angeboten werden muss aber vom Kunden au erhalb der ATEX Zone installiert werden Die Firma MIL...

Page 26: ...ebaut werden soll f r eine effiziente Bel ftung sorgen Die Vakuumpumpe arbeitet nur auf einer horizontalen Fl che die die Gesamtmasse der Pumpe und ihres Zubeh rs aufnehmen kann Der Betrieb auf einer...

Page 27: ...ugstutzen in Betrieb gesetzt werden Zu d nne und oder zu lange Saugleitungen verringern die Leistungen der Pumpen Der Saugdruck darf den Atmosph rendruck nicht berschreiten F hren Sie nach der Install...

Page 28: ...der Sonde die Herstelleranweisungen in der Anlage beachten F r die Sondenverwaltung siehe EN80079 37 6 5 Die einwandfreie Funktion des Temperaturf hlers wird vor dem Versand gepr ft Inbetriebnahme 3...

Page 29: ...re Vorsichtsma nahmen zu treffen Diese Arbeiten m ssen von qualifiziertem und befugtem Personal durchgef hrt werden Bei Nichtbeachtung der Herstellerempfehlungen und Nichtgebrauch von Originalteilen b...

Page 30: ...n Dichtung anbringen Muttern festschrauben 1 Anzahl der Separatorpatronen E65 R E100 R E200 R E300 R Eine Zwei Drei Ansauggitter 3 4 Vor dem Ansaugstutzen 1 der Pumpe befindet sich ein Gitter Je nach...

Page 31: ...Filter ber den Anschlusspunkt an Erde an um die Erdung zu gew hrleisten Schwimmerableiter 3 4 5 Dieser labscheider spritzt das l aus der Abscheidekartusche wieder in die Pumpe Er befindet sich im Fac...

Page 32: ...t 2 2 Ansauggitter verstopft 2 3 Ansaugfilter verstopft Option 2 4 Abscheidekartusche verstopft 2 5 Zu lange oder zu kleine Schl uche die einen zu gro en Druckverlust bewirken ZWISCHENFALL M GLICHE UR...

Page 33: ...stances explosives OUI NON L appareil contient il des substances radioactives OUI NON Autres OUI NON CMR canc rig ne mutag ne reprotoxique Si pr sence de mati res radioactives ou explosives num rer le...

Page 34: ...evice contain explosive substances YES NO Does the device contain radioactive substances YES NO Others YES NO CMR carcinogenic mutagenic reprotoxic S If radioactive or explosive materials are present...

Page 35: ...D claration de conformit CE EC conformity declaration 517976 04 33...

Page 36: ...www mils fr Plaque de caract ristiques Sp cification plate...