Linearization Parameters, P390 - P396
These parameters are used to compensate for non-linear response of the weighing
system to the BW100. Refer to Recalibration\Linearization for details and example on
the use of these parameters.
P390
linearization
Enables or disables the linearization function.
entry: 0 = off
1 = on
P391
linearizer, point 1
enter the load, in units of P017, for point 1
P392
compensation, point 1
enter the calculated compensation, in percent, for compensation point 1
P393
linearizer, point 2
enter the load, in units of P017, for point 2
P394
compensation, point 2
enter the calculated compensation, in percent, for compensation point 2
P395
linearizer, point 3
enter the load, in units of P017, for point 3
P396
compensation, point 3
enter the calculated compensation, in percent, for compensation point 3
End of Linearization Parameters.