![Milltronics Accumass BW100 Instruction Manual Download Page 55](http://html1.mh-extra.com/html/milltronics/accumass-bw100/accumass-bw100_instruction-manual_1796978055.webp)
MESSAGE REQUESTS
Message requests must be transmitted from the host to the BW100 in the
following format.
som DEVICE MT eom
Example:
Data
ASCII
Example
Field
Character
Description
som
STX
start of message
DEVICE
01
for BW100 # 1
MT
50
material flow rate request
eom
CR
end of message
MESSAGE RESPONSES
The BW100 response to a flow rate (MT=50) load (MT=51) or speed (MT=52)
message request is in the following format.
som DEVICE MT READING eom
Example:
Data
ASCII
Example
Field
Character
Description
som
STX
start of message
DEVICE
00
from BW100 # 0
MT
50
material flow rate response
READING
392.5
is 392.5
eom
CR
end of message
The response to a material total (MT=53) message request is in the following format.
som DEVICE MT READING UNITS eom
Example:
Data
ASCII
Example
Field
Character
Description
som
STX
start of message
DEVICE
01
from BW100 # 1
MT
53
material total response
READING
129.2
is 129.2
UNITS
t
metric tonnes
eom
CR
end of message
OPERATION