OM-281136 Page 12
E. Air-Cooled Quick Wrap
Ref. 279589-A / Ref. 282491-A
B
A
.
Always use air-cooled quick wrap with sleeve installed.
C
D
E
Part
No.
Dimensions
Pipe Fit Diameter
(w/Blanket Insulating Pad
And Sleeve)
Weight
A
B
C
D
E
301452
78 in.
(1981 mm)
3.7 in.
(94 mm)
6.5 in.
(165 mm)
2.4 in.
(61 mm)
62.75 in.
(1594 mm)
Min. 1.5 in. (38.1)
Max 10 in. (254 mm)
15 lb
(6.8 kg)
Maximum Air-Cooled Quick Wrap Heating Tool Preheat Temperatures: 392
F (200
C), 600
F (316
C) with added
preheat insulation.
.
Air-cooled quick wrap life will be shortened and damage will occur if exposed to temperatures above 392
°
F (200
°
C) without a layer of preheat
insulation.
.
Preheat insulation is recommended for part temperatures above 302
5
F (150
5
C) due to variances in thermocouple locations.
Part No.
Description
195376
Insulation, Preheat (0.50 X 6 X 240)
204669
Insulation, Preheat (0.50 X 6 X 120)
211474
Insulation, Preheat (0.50 X 12 X 120)
.
Using wider insulation can help retain heat in the workpiece and reduce time getting to temperature.
4-5. Environmental Specifications
A. IP Rating
IP Rating
IP23S
This equipment is designed for outdoor use. It may be stored, but is not intended to be used for induction heating outside during precipitation
unless sheltered.
IP23S 2014
−
06
B. Temperature Specifications
Operating Temperature Range
Storage/Transportation Temperature Range
14 to 104
°
F (-10 to 40
°
C)
−
4 to 131
°
F (
−
20 to 55
°
C)
Temp1_2016- 08