OM-281136 Page 13
SECTION 5
−
INSTALLATION
5-1. Selecting a Location
1
ArcReach Heater
2
Lift Handle
Use lift handles to move and lift
induction heating accessory.
Operate in upright position.
.
Do not block air intake. Avoid
operating on grass. Concrete
is okay.
Movement, Location, and Airflow
18 in. (460 mm)
18 in. (460 mm)
1
2
2
1 in. (25.4mm)
!
Do not move or operate unit where it could tip.
Ref. oc_dynasty 2015-04
5-2. Selecting Weld Cable Sizes
The ArcReach Heater requires 2/0 (70 mm) minimum cable size to minimize voltage drop in the cable.
.
Ensure cable connecters are clean and tight to minimize voltage drop in the connectors.
Maximum cable length is 200 ft (61 m) from welding power source, 400 ft (122 m) total loop length.