OM-281136 Page 32
SECTION 6
−
SYSTEM CONTROLS AND COMPONENTS
1
Run Button
Press button to start output.
2
Stop Button
Press button to stop output.
3
Help Button
Press button to see a description and in-
structions for a particular screen.
4
Program Driven Buttons
Use these buttons to change function
based on screen selected.
5
Menu Button
Press button to go to the home screen in
main menu.
6
Scroll Up/Down Buttons
Press button to navigate through the
options list. Use to select language.
7
Temperature LED for
°
F
When LED is illuminated, the display will
show a temperature value in
°
F
8
Temperature LED for
°
C
When LED is illuminated, the display will
show a temperature value in
°
C
9
Maximum Temperature Display
Display shows maximum temperature of all
connected thermocouples.
.
Display will read OPEN when no
thermocouples are connected.
10 Minimum Temperature Display
.
Display will read OPEN when no
thermocouples are connected.
Display shows minimum temperature of all
connected thermocouples.
11 Fault LED
When LED is illuminated, the heating
process has stopped.
12 Heating LED
When LED is illuminated, the heating
process is active.
6-1. System Controls
8
7
3
2
1
12
11
Ref. 276675-B
10
9
4
5
6
OPEh