OM-281136 Page 24
5-11. Installing Air-Cooled Quick Wrap (Also see Sections 5-12 and 5-13)
1
!
Do not hang cables on steel
brackets, hangers, or other
mechanisms.
1
Air-Cooled Quick Wrap
2
Preheat Insulation
3
Workpiece
4
Weld Joint
5
Cinch Clip
6
Latching Handle
Place air-cooled quick wrap around
pipe (and insulation if installed).
A single quick wrap is often used
directly over a joint or on the end of a
pipe.
Two quick wraps can be used to cover
a wider heat zone to introduce more
power into a larger part.
.
Keep heating tool leads between
ArcReach Heater extension cable
and workpiece together to
increase heating performance
and minimize unintentional
heating of nearby objects.
.
Position the quick wrap close to
the weld joint to decrease the time
spent to reach the desired temper-
ature. Protect quick wrap from
weld heat and grinding with a weld
blanket or move quick wrap further
from joint.
.
Smaller pipe diameters will
provide more of a gap and cause
a requirement for a tighter cinch
under pipe.
2
2
3
1
3
2
2
4
Ref. 282308-A
1
1
4
5
5
6
5
6
.
Cinch up tight.
.
Cables may be suspended above the workpiece to
keep the area under it clear of cables. Use plastic cable ties,