![Miller 907684001 Owner'S Manual Download Page 69](http://html1.mh-extra.com/html/miller/907684001/907684001_owners-manual_1796041069.webp)
.
A complete Parts List is available at www.MillerWelds.com
OM-270536 Page 61
11-4. Output Control And Trigger Functions For DX Models
A. Remote (Standard), 2T, And 4TE Torch Trigger Operation
Current (A)
Preflow
Initial Amps
Initial Slope
Final Slope
Postflow
Main Amps
Final Amps
R
R
P/H
Maintained Switch
Foot Or Finger
Remote Control
P/H = Push and hold trigger
R = Release trigger
.
When a foot or finger remote current control is connected to the welding power source, initial amps, initial
slope, final slope and final amps are controlled by the remote control, not by the welding power source.
P/R
P/R
P/R = Push and release trigger.
.
If torch trigger is held more than 3 seconds, operation reverts to RMT STD (Remote Standard) mode.
.
For first torch trigger push & release, if trigger is held more than 3 seconds, trigger cycle ends.
P/R
P/R
P/R
P/R
P/R = Push and release trigger;
*Push and releasing during final slope will break the arc and go to postflow.
*P/R
.
When a remote switch is connected to the welding power source, use the remote switch to control the weld cycle.
Amperage is controlled by the welding power source.
Application:
Use 4T Momentary trigger method when the functions of a remote current control are desired, but only a remote on/off
control is available.
Time
Standard
Remote 2T
Remote 4TE