![Miller 907684001 Owner'S Manual Download Page 60](http://html1.mh-extra.com/html/miller/907684001/907684001_owners-manual_1796041060.webp)
.
A complete Parts List is available at www.MillerWelds.com
OM-270536 Page 52
9-4. Accessing User Setup Menu: DC TIG Lift-Arc And DC Stick
1
Menu Button
Press and hold Menu button for ap-
proximately 2 seconds to access
machine configuration menus. Use
Menu button to cycle through para-
meters that can be set.
2
Parameter Display
3
Setting Display
4
Amperage Adjustment Control
Rotate amperage adjustment con-
trol to adjust parameter setting.
.
To exit menu, press and hold
Menu button until Menu Off is
displayed.
1
ON
OUT
MENU
2
3
4
USER
Trigger Mode Selection
[RMT] [STD]
Typical setting for a remote foot or hand control.
RMT STD requires a maintained contact closure to
enable weld output. Amperage can be controlled
with a remote potentiometer, or it can be set at the
control panel.
[OUT] [ON]
Output on.
!
Weld output terminals are energized at all
times when displays read [OUT] [ON].
No remote control or trigger required. Amperage
can be controlled at the control panel or with a re-
mote potentiometer. Blue output on LED illuminates
to indicate output is on.
271723-B
Schedule 1
Schedule 2
LIFT ARC
LIFT ARC
Schedule 1
Schedule 2
Summary of Contents for 907684001