![Miller 907684001 Owner'S Manual Download Page 56](http://html1.mh-extra.com/html/miller/907684001/907684001_owners-manual_1796041056.webp)
.
A complete Parts List is available at www.MillerWelds.com
OM-270536 Page 48
8-5. Accessing User Setup Menu: DC Stick
1
Menu Button
Press and hold Menu button for ap-
proximately 2 seconds to access
machine configuration menus. Use
Menu button to cycle through para-
meters that can be set.
2
Parameter Display
3
Setting Display
4
Amperage Adjustment Control
Rotate amperage adjustment con-
trol to adjust parameter setting.
.
To exit menu, press and hold
Menu button until Menu Off is
displayed.
1
ON
OUT
2
3
4
ON
HOTS
Trigger Mode Selection:
[RMT] [STD]
Typical setting for a remote foot or hand control.
RMT STD requires a maintained contact closure to
enable weld output. Amperage can be controlled
with a remote potentiometer, or it can be set at the
control panel.
[OUT] [ON]
!
Weld output terminals are energized at all
times when displays read [OUT] [ON].
No remote control or trigger required. Amperage can
be controlled at the control panel or with a remote po-
tentiometer. Blue output on LED illuminates to indic-
ate output is on.
Arc Starting Mode Selection:
MENU
USER
[HOTS] [ON]
Provides additional amperage while striking the elec-
trode to prevent the electrode from sticking.
[HOTS] [OFF]
No additional starting amperage to assist in starting the
electrode.
Or
247218-C
HF START
Schedule 1
Schedule 2
LIFT ARC
Summary of Contents for 907684001
Page 6: ......
Page 46: ...A complete Parts List is available at www MillerWelds com OM 270536 Page 38 Notes...
Page 79: ...OM 270536 Page 71 Figure 14 2 Circuit Diagram For Maxstar 210 255981 H...
Page 88: ...Notes...
Page 89: ...Notes...
Page 90: ...Notes...