![Miller 907684001 Owner'S Manual Download Page 68](http://html1.mh-extra.com/html/miller/907684001/907684001_owners-manual_1796041068.webp)
.
A complete Parts List is available at www.MillerWelds.com
OM-270536 Page 60
11-3. Sequencer And Weld Timer For DX Model
OFF
20A
OFF
ISLP
INTL
INTL
Sequencer Control With Weld Timers ON
This function is available while using the TIG
process, but is disabled if a remote foot or
fingertip control is connected while in the RMT
STD mode. When active, the sequencer
controls the following parameters of the weld
cycle:
Initial Amperage
Range is 2
−
210 amps AC,1
−
210 amps DC
Initial Time*
Range is OFF to 25.0T (seconds)
Initial Slope Time
Range is OFF to 50.0T (seconds)
Final Slope Time
Range is OFF to 50.0T (seconds)
Final Amperage
Range is 2
−
210 amps AC,1
−
210 amps DC
Final Time*
Range is OFF to 25.0T (seconds)
OFF
10A
FSLP
FNL
OFF
FNL
.
When a remote switch is connected to the
welding power source, use the remote switch
to control the weld cycle. Amperage is
controlled by the welding power source.
*enabled features with weld timer On (see Section
Weld Timer
With Weld Timer enabled, press Amperage (A)
button, and turn amperage adjustment control to
set weld time. Range is Off or 0.1
−
99.9 and
100
−
OFF
WELD
Summary of Contents for 907684001
Page 6: ......
Page 46: ...A complete Parts List is available at www MillerWelds com OM 270536 Page 38 Notes...
Page 79: ...OM 270536 Page 71 Figure 14 2 Circuit Diagram For Maxstar 210 255981 H...
Page 88: ...Notes...
Page 89: ...Notes...
Page 90: ...Notes...