84
No speed reading
Speed reading to slow or
to fast
No rate in rate window
Rate will not change or
adjust
Nozzle output not equal
Boom section output not
equal
Boom section will not turn
on
Poor tank agitation
Hydraulic drive pump
keeps stopping
Blown out fuse
Poor wire connection or bad wire
Wrong calibration number
SP-1 or SP-2 setting wrong
SP-1 Wheel drive
SP-2 Radar gun
Flow meter not working
Regulating valve not working
Tips plugging
Tip screens plugging
In line filter plugging
Nozzle check valve sticky or swollen
ON/OFF valve not opening completely
No signal from control box
Circuit breaker released in ON/OFF
boom ball valve
Agitation valve closed
Agitation valve not completely open
Self cleaning filter ON/OFF valve not
open
Plugged agitation nozzle(s)
To much oil flow from tractor
Check and replace fuse
Clean and check connection
Check for break in wire
Verify calibration number
Verify setting - See RAVEN
owners manual
Check connections and wires
Check for foreign material in rotor
Check transducer
See RAVEN owners manual for
instructions
Check connections and wiring
Check for foreign material in
valve
See RAVEN owners manual for
instructions
Clean tips
Clean screens
Clean in line filter
Clean or replace check valve
Clean or replace ON/OFF valve
Check connections and wires for
breaks
Unplug ON/OFF valve connec-
tion on sprayer for one minute
and replug
Open valve
Open valve
Open valve
Clean nozzles
Reduce oil flow from tractor
See pump owners manual for
details
Problem
Possible Cause
Solution
Troubleshooting Guides (continued)
RAVEN Controller
Summary of Contents for 500 BW
Page 6: ......
Page 31: ...27 Spray Tip Wear...
Page 38: ...34 TeeJet Air Induction Spray Tips At Various Speeds And Pressures 20 Inch Tip Spacing...
Page 94: ......