66
Cleaning The Sprayer
Keeping your sprayer clean helps assure a long service life. Many pesticides can quickly corrode
metal parts in the spraying system. Chemicals remaining in the sprayer can react with a second
chemical introduced to the system and offset its effectiveness.
Manual Control Rinse System
Short Term Shutdown
Rinsing the Product Pump, Controls and Boom Lines Leaving the Product Tank Undisturbed:
1.
Turn OFF the “Agitation Valve” located on the front control stand - If so desired.
2.
Turn OFF the Self Cleaning Filter valve located at the front left corner of the operator platform -
If so desired.
Self Cleaning
Filter Valve
Agitation Valve
3.
Turn the manual 3 way ball valve identified as “Valve E” (located under platform on left side of
sprayer) to “Rinse Tank” (Point handle forward).
4.
Start product pump, drive at normal speed, turn complete boom ON and spray as normal until
clean liquid comes out of sprayer tips.
5.
Turn boom OFF, stop the product pump and stop the tractor.
6.
Turn the manual 3 way ball valve identified as “Valve E” (located under platform on left side of
sprayer) to “Product Tank” (Point handle toward rear of sprayer).
7.
Turn ON the “Agitation Valve” located on the front control stand - If so desired.
8.
Turn ON the Self Cleaning Filter valve located at the front left corner of the operator platform.
PRODUCT
TANK
OFF
ON
RINSE
TANK
E
F
OFF
Summary of Contents for 500 BW
Page 6: ......
Page 31: ...27 Spray Tip Wear...
Page 38: ...34 TeeJet Air Induction Spray Tips At Various Speeds And Pressures 20 Inch Tip Spacing...
Page 94: ......
Page 96: ...2007 by Miller St Nazianz Inc...