57
NOTE:
Some chemicals tend to foam when agitated. If foaming occurs, throttle back the agitation
valve until the foaming stops. If you change the agitation valve setting, you may have to adjust the
pressure on the tractor control box. This adjustment would not be necessary with a RAVEN rate
controller.
NOTE:
There are anti foaming agents available:
•
Part No. 07.06881 Shakedown, Liquid - 1 Pint
•
Part No. 07.06880 Shakedown, Dry - 1/2 lb. jar
•
Part No. 07.06879 Shakedown, Water Soluble Packets - 30 per case
10.
If you are mixing more than one chemical into the product tank, you should check with your
chemical supplier to make sure you add the chemicals in the correct sequence to insure
proper mixing.
11.
Be certain to clean and dispose of empty chemical containers properly. Follow the instructions
on the container.
NOTE: DO NOT
use the chemical inductor system for powder type chemicals. Flowable granular
chemicals are acceptable.
IMPORTANT: The “Tee” fitting at the bottom of the chemical inductor is a special fitting with
a venturi nozzle on the inside. NEVER operate the chemical inductor without the venturi
nozzle installed.
Standard Control Box
Pressure Adjust Switch
Pressure Gauge
Summary of Contents for 500 BW
Page 6: ......
Page 31: ...27 Spray Tip Wear...
Page 38: ...34 TeeJet Air Induction Spray Tips At Various Speeds And Pressures 20 Inch Tip Spacing...
Page 94: ......
Page 96: ...2007 by Miller St Nazianz Inc...