9.6.4 Exposure Signal (EXP)
The EXP signal is positiv active if register 7, Bit 8 = 0, negativ
active if register 7, Bit 8 = 1.
The EXP signal is synchronized with an internal line signal, and
effective exposure starts and stops up to 136 sensor clocks after
assertion/deassertion of the EXP signal.
The effective exposure time tshut is synchronised with an internal
line signal.
LDV
Image n-1
Image n+1
Image n+1
Image n
Image n
tshut
FDV
EXP
EXP Signal can be asserted even while the previous image is out-
put (FDV active), provided that exposure time set by the
is longer than the FDV active time.
EXP is also used as enable signal for ImageBLITZ shutter release.