Configuration MC130x
Users Manual Rev. 2.1
number of lines
•
•
•
address of first displayed pixel of a line (in steps of 10)
address of last displayed pixel of a line (in steps of 10)
6.4.1 Number of the first displayed line
Register r1 defines the first line to be displayed.
Command:
:r1
<x
2
x
1
x
0
>
<x
2
x
1
x
0
>
... Range 000h ...3ffh
Response:
none
Example: :r1100
100h = 256 (image starts at line 256)
L
If dual column binning is activated, r1 is doubled
within the camera logic
6.4.2 Number of lines
Register r3 defines the number of lines to output.
Command:
:r3
<x
2
x
1
x
0
>
<x
2
x
1
x
0
>
... Range 000h ...3ffh
Response:
none
Example: :r3200
200h = display 513 lines
L
The sum of r1 and r3 must be
≤
0x3ff/1023 or
0x1ff/511 if dual column binning is activated!
25