When the boiler is set up for outside temperature control (with or without a room
thermostat or room unit) adjusting this setting raises or lowers the heating curve.
This has the effect of increasing or lowering the boiler water temperature and ultimately
increasing or lowering the room temperatures as the cooler or warmer water circulates
through the heat emitters.
Raising or lowering the building ambient temperature is possible without adjusting the
setting of the room thermostat or room unit. If the boiler is set up to work without outside
temperature reference then the feature has no function. To access press "MENU" button
as before then press “+” or “-“ to enter a value then press “-MENU-“ button once to
confirm entry. The default value for this setting is 20
o
C
8.4 Time/day function
Having selected this function, there is a subprogram with two options: the correct time, in
minutes To change the time press “-MENU-“ button once and the use the press “+” or “-“
to change the time then press “-MENU-“ button once to confirm entry. the day To change
the day press “-MENU-“ button once and the use the press “+” or “-“ to set the day then
press “-MENU-“ button once to confirm entry.
38.5 Setting the ch timer
When a RE2132 room unit is fitted the built in timer function takes priority over the
boilers timer control. In this case the boiler timer should be set to 00.00 hours. This
programme enables the setting of 3 time blocks (3 start and 3 end times) per day (24
hours) for higher and lower room temperatures. This menu has two submenus: a. the
days of the week b. the start and end times of each block To access this function from
the main menu display press “MENU” button for three seconds. You will arrive at
“PARTY O HOURS” in the display. Press the “+” button three times to arrive at SET CH
TIMER Press the "MENU" button once and the first display will be "Monday" use the "+"
and "-" buttons to scroll through this submenu to reach the day you want to change.
Having found the correct day, press the "MENU" button once to arrive at
“CopySU>MO” ignore this and press the "+” button once to arrive at “SWITCH ON 1”
“MO 00:00”
Press the "MENU" button once and the hours “00” part of the display will start flashing.
This sets the hour the heating will start for the first of three possible on times per day
Adjust the hour by pressing the "+" and "-" buttons. When the correct time is displayed
confirm by pressing "MENU" button once and the minutes part of the display “00” will
start flashing.
Adjust the minutes by pressing the "+" and "-" buttons. When the correct time is
displayed confirm by pressing "MENU" button once. Press the "+” button once to arrive
at “SWITCH OFF 1” “MO 00:00”
This sets the hour the heating will switch off for the first of three possible off times per
day.
Adjust the hour by pressing the "+" and "-" buttons.
When the correct time is displayed confirm by pressing "MENU" button once and the
minutes part of the display “00” will start flashing.
Adjust the minutes by pressing the "+" and "-" buttons. When the correct time is
displayed confirm by pressing "MENU" button once.
Press the "+” button once to arrive at
“SWITCH ON 2” “MO 00:00”
Repeat as above to programme all 3 start and 3 end times
If you wish to ignore any periods then simply enter "0.00".