![Mikrofill Ethos 28 Series Installation And Operating Manual Download Page 40](http://html1.mh-extra.com/html/mikrofill/ethos-28-series/ethos-28-series_installation-and-operating-manual_1794276040.webp)
b. the start and end times of each block
For programming, repeat as for section CH timer. During programmed off periods
Combi models will maintain a minimum storage temperature of 40
o
C.
For appliances connected to hot water cylinder for this function to operate temperature
control has to be provided with a sensor (available from Mikrofill). When hot water
temperature control is provided by a cylinder thermostat this function is not recognised.
26.6 Setting MR03 times
When a MR 03 secondary circuit control unit has been fitted then this programme
enables the setting of 3 time blocks (3 start and 3 end times) per day (24 hours) for
higher and lower temperatures for a second central heating circuit. Note unless a MR 03
is connected this function will not be seen.
26.7 Night-time lower 0oc.
This is used to programme the value for the night time set back temperature in relation to
the room temperature during the day.
NOTE ! If the difference between the daytime temperature and night time setback
temperature is considerable, the start time of the central heating unit must be set earlier
than required to compensate.
Statistically, it has been proven that a night time decrease of 5°C is best; if a lower night-
time temperature is set, heating in the morning requires too much energy.
With “SETBACK” displayed on the screen press "MENU" button until “_____”
o
C flashes
on the screen. press “+” or “-“ to enter a value then press “-MENU-“ button once to
confirm entry.
26.8 Holiday function
Use the "+" and "-" buttons to set the number of days of the holiday period.
During this period, the night time temperature will be maintained, while the tap water
temperature will be set at a minimum of 20°C.
If you are away for an extended period then to save energy adjust the night time
temperature to 10°C.
After the number of days has expired, the unit will start operating according to the clock
programme set.
Remember when you return to re-adjust the night time temperature to it’s original setting.
Having completed the setting, press the "MENU" button to confirm the new value.