37.11 Test button
Checks overheat safety feature. When the burner is on and the button depressed, the
burner will shut down when button released, the unit will start up again.
Checks pump function. When the burner is off and the button depressed, the pump will
run at 100% speed for approx 2 seconds.
37.12 General
To access the programming mode for times, temperatures, etc., the "Menu" button must
be depressed for
3 seconds
the screen will briefly display “-MENU-“ and display a menu
option. Use the "+" and "-" buttons to scroll through the various options and the "MENU"
button to select and confirm changes.
38. Programming Menu options
38.1 Party
This function allows you to extend the current heating period. To access the party option
press the “-MENU-“ button once and “____hours” will flash on the screen, press “+” or “-“
to enter a value then press “-MENU-“ button once to confirm entry.
After expiry of the extension time set, the night-time temperature will start; if the lower
night temperature had already started at the time of setting the party time, the daytime
temperature will be obtained for the duration of the time set, after which the night
-time
temperature will be resumed.
Range 0 – 24 hours. Default 0 hours.
38.2 Hot Water Temperature
For S type appliances (COMBIS) this function allows you to select the maximum hot
water temperature. For H and HS type appliances connected to hot water cylinder where
temperature control is provided with a sensor (available form Mikrofill) this function
allows you to select the maximum temperature for the water in the cylinder.
To access the “TEMP DHW” option press the "MENU" button until “_____”
o
C flashes on
the screen. press “+” or “-“ to enter a value then press “-MENU-“ button once to confirm
entry.
Temperature range 40 - 60
o
C. Default 60
o
C.