24.8 General
To access the programming mode for times, temperatures, etc., the "Menu" button must
be depressed for
3 seconds
the screen will briefly display “-MENU-“ and display a menu
option. Use the "+" and "-" buttons to scroll through the various options and the "MENU"
button to select and confirm changes.
25. Menu options
25.1 Party/Extension Time
This function allows you to extend the current heating period. To access the party option
press the “-MENU-“ button once and “____hours” will flash on the screen, press “+” or “-“
to enter a value then press “-MENU-“ button once to confirm entry. After expiry of the
extension time set, the night-time temperature will start; if the lower night temperature
had already started at the time of setting the party time, the daytime temperature will be
obtained for the duration of the time set, after which the night-time temperature will be
resumed.
Range 0 – 24 hours. Default 0 hours.
26. User programming
26.1 Hot Water Temperature
This function allows you to select the maximum hot water temperature. For appliances
connected to hot water cylinders where temperature control is provided with a sensor
(available form Mikrofill) this function allows you to select the maximum temperature for
the water in the cylinder. To access the “TEMP DHW” option press the "MENU" button
until “_____”
o
C flashes on the screen. press “+” or “-“ to enter a value then press “-
MENU-“ button once to confirm entry. Temperature range 40 - 60
o
C. Default 60
o
C.
26.2 Day temperature function
When the boiler is set up for outside temperature control (with or without a room
thermostat or room unit) adjusting this setting raises or lowers the heating curve. This
has the effect of increasing or lowering the boiler water temperature and ultimately
increasing or lowering the room temperatures as the cooler or warmer water circulates
through the heat emitters. Raising or lowering the building ambient temperature is
possible without adjusting the setting of the room thermostat or room unit. If the boiler is
set up to work without outside temperature reference then the feature has no function.
To access press "MENU" button as before then press “+” or “-“ to enter a value then
press “-MENU-“ button once to confirm entry. The default value for this setting is 20
o
C
26.3 Time/day function
Having selected this function, there is a subprogram with two options:
the correct time, in minutes
To change the time press “-MENU-“ button once and the use the press “+” or “-“ to
change the time then press “-MENU-“ button once to confirm entry.
the day