2.4
Water Intake Monitoring - Water Control System (WCS)
Water intake monitoring will register a shut-off faucet, too-low water pressure,
or a seal problem (such as a missing lint filter).
If a fault occurs, the program is stopped and the fault message
Water intake
fault
is displayed.
Water intake fault
is issued under the following conditions:
if
after
5 seconds
of water intake the
flow meter (B3/4)
does not register
a signal,
if
after
150 seconds
of water intake the
imbalance sensor (ADS)
does
not register an increase of at least
0.3” wc
,
if
the
flow meter (B3/4)
registers
4 gallons (15 liters)
of water intake and
the water pressure as measured by the
imbalance sensor (ADS)
did not
increase to at least
0.8” wc
,
or if the water volume in one block rises above a critical threshold.
Hot water only:
When the
Hot water
intake option is selected, the fault is
not saved
and the program that is running is continued with cold water.
2.5
Water Overflow Monitoring
If the overflow level of 10” wc is reached, the drain pump (M8) runs until the
level drops by 3” down to 7” wc.
2.6
Flow Meter (B3/4)
The flow meter is integrated into the water path control unit and generates
impulses depending on the water flow.
Based on these impulses, the electronic calculates the amount of water that
has run into the suds container.
Advantages:
The flow meter registers the amounts of water flowing in more accurately,
compared to previous systems without this sensor.
The imbalance sensor (ADS) monitors the function of the flow meter.
During a malfunction or total failure of the flow meter, the water intake is
controlled via level-controlled fill.
2.7
Water Path Control Unit and Motor (M24)
Activation by electrical motor. Measurements are taken via a slip contact
in the water path control unit.
Water path control unit with an additional fifth position for bleach.
Summary of Contents for TOUCHTRONIC W 4842
Page 1: ...TECHNICAL INFORMATION W 48xx Washers US Models 2018 Miele USA ...
Page 11: ...Technical Information 11 W 48xx 010 Casing Lid Shipping Struts ...
Page 16: ...Technical Information 16 W 48xx 020 Door Magnet Lock ...
Page 21: ...Technical Information 21 W 48xx 030 Suds Container Drum Bearing Heater Element ...
Page 27: ...Technical Information 27 W 48xx 040 Water Intake ...
Page 31: ...Technical Information 31 W 48xx 050 Drainage ...
Page 33: ...Technical Information 33 W 48xx 060 Drive ...
Page 37: ...Technical Information 37 W 48xx 070 Fascia Panel Electronic ...
Page 80: ...Technical Information 80 W 48xx 090 Electrical System ...