Technical Information
35
W 48xx
3
Fault Repair
3.1
Defective Drum Drive
Cause:
Defective drive.
Remedy:
1. Check drive.
2. Check drive MXT 40; refer to Section 060-4.3.
4
Service
4.1 Tachogenerator
Danger!
Risk of electric shock when working on low-voltage components.
In the power electronic (ELP), there is no galvanic isolation from the power
supply.
When working on a washer connected to the power supply, be aware of the
risk of potential voltage on low-voltage components.
4.2
Mounting the Toothed V-Belt
Figure 060-1:
Mounting the Frontloader Toothed V-Belt
Fit the toothed V-belt onto the pulley with the aid of a mounting lever (mat.
no. 05057690).
4.3
Drive MXT 40
Check drum and drive for free movement. If the drive is blocked, remove the
Summary of Contents for TOUCHTRONIC W 4842