Action after a Power Failure
The appliance automatically continues the program at the exact point where it
stopped when the power cut out.
2.3
Programming Functions (HY IV E)
2.3.1
Water Plus
Setting for
Water Plus
.
When
Water Plus
is selected, the water level is raised and/or an additional
rinse cycle is carried out.
2.3.2 Gentle
Cycle
Setting for gentle cycle.
Selecting the gentle cycle reduces the drum movement. Fabrics are washed
gently.
For lightly soiled laundry.
2.3.3 Suds
Cooling
At active suds cooling, in programs 167°F and higher, cold water is taken in
at the end of the main wash cycle to cool the suds.
This reduces the danger of scalding by draining suds, and it protects drain
pipes that are not high-temperature resistant.
2.3.4 Memory
When the memory function is activated, the
program settings
(made at the
start of a program) and any special settings (such as temperature and spin
speed) are saved. When the same program is selected again, these special
settings are automatically activated.
2.3.5
Buzzer
Activate the buzzer to sound at program end and during rinse stop, and set
the buzzer tone.
Note:
In case of a fault, the buzzer also sounds even if it has not been activated.
2.3.6 Language
The active language is used for the operating, programming and service
modes.
2.3.7 Contrast
The contrast of the display can be adjusted to suit the existing lighting
conditions.
Summary of Contents for TOUCHTRONIC W 4842
Page 1: ...TECHNICAL INFORMATION W 48xx Washers US Models 2018 Miele USA ...
Page 11: ...Technical Information 11 W 48xx 010 Casing Lid Shipping Struts ...
Page 16: ...Technical Information 16 W 48xx 020 Door Magnet Lock ...
Page 21: ...Technical Information 21 W 48xx 030 Suds Container Drum Bearing Heater Element ...
Page 27: ...Technical Information 27 W 48xx 040 Water Intake ...
Page 31: ...Technical Information 31 W 48xx 050 Drainage ...
Page 33: ...Technical Information 33 W 48xx 060 Drive ...
Page 37: ...Technical Information 37 W 48xx 070 Fascia Panel Electronic ...
Page 80: ...Technical Information 80 W 48xx 090 Electrical System ...